1.6k citations · 6.2k across the 32 of their papers we have counts for
17 papers · 1 filter
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
LUX-ZEPLIN (LZ) Technical Design Report
B. J. Mount, S. Hans, R. Rosero +259
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
D. S. Akerib, S. Alsum, H. M. Araújo +98
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…
Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
J. R. Verbus, C. A. Rhyne, D. C. Malling +12
We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galact…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Chromatographic separation of radioactive noble gases from xenon
LUX Collaboration, D. S. Akerib, H. M. Araújo +96
The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…
FPGA-based Trigger System for the LUX Dark Matter Experiment
D. S. Akerib, H. M. Araujo, X. Bai +100
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…
Measurements of wavelength-dependent double photoelectron emission from single photons in VUV-sensitive photomultiplier tubes
C. H. Faham, V. M. Gehman, A. Currie +3
Measurements of double photoelectron emission (DPE) probabilities as a function of wavelength are reported for Hamamatsu R8778, R8520, and R11410 VUV-sensitive photomultiplier tube…
High Voltage in Noble Liquids for High Energy Physics
Edited by B. Rebel, C. Hall with contributions from E. Bernard, C. H. Faham +12
A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, a…
The Large Underground Xenon (LUX) Experiment
D. S. Akerib, X. Bai, S. Bedikian +91
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMP…
The LUX Prototype Detector: Heat Exchanger Development
D. S. Akerib, X. Bai, S. Bedikian +47
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble elemen…
An Ultra-Low Background PMT for Liquid Xenon Detectors
D. S. Akerib, X. Bai, E. Bernard +64
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diam…
Radio-assay of Titanium samples for the LUX Experiment
D. S. Akerib, X. Bai, S. Bedikian +63
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construct…