176 citations · 333 across the 10 of their papers we have counts for
10 papers · 1 filter
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. Villa, L. Terenzi, M. Sandri +71
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…
Optimization of Planck/LFI on--board data handling
M. Maris, M. Tomasi, S. Galeotta +34
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its teleme…
Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
J. Varis, N. J. Hughes, M. Laaninen +26
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and t…
Thermal susceptibility of the Planck-LFI receivers
L Terenzi, M J Salmon, A Colin +33
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low…
Planck-LFI radiometers tuning
Francesco Cuttaia, Aniello Mennella, Luca Stringhetti +33
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Inst…
Cryogenic environment and performance for testing the Planck radiometers
L. Terenzi, M. Lapolla, M. Laaninen +21
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) ha…
The linearity response of the Planck-LFI flight model receivers
A. Mennella, F. Villa, L. Terenzi +37
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…
Noise Properties of the Planck-LFI Receivers
P. Meinhold, R. Leonardi, B. Aja +47
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of t…
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. Mennella, M. Bersanelli, R. C. Butler +83
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. Bersanelli, N. Mandolesi, R. C. Butler +109
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmi…