activity
20112022
most citedIndication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment

1.2k citations · 2.1k across the 15 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

7 papers · 1 filter

physics.ins-det2022★ 1 cited

The Double Chooz antineutrino detectors

Double Chooz Collaboration, H. de Kerret, Y. Abe +247

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were meas…

physics.ins-det2016★ 13 cited

Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment

Double Chooz collaboration, Y. Abe, T. Abrahão +146

During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical…

physics.ins-det2014★ 15 cited

Ortho-positronium observation in the Double Chooz Experiment

Y. Abe, J. C. dos Anjos, J. C. Barriere +143

The Double Chooz experiment measures the neutrino mixing angle by detecting reactor via inverse beta decay. The positron-neutron space and time coincidence allow…

physics.ins-det2014★ 15 cited

Precision Muon Reconstruction in Double Chooz

Double Chooz collaboration, Y. Abe, J. C. dos Anjos +141

We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liq…

physics.ins-det2013★ 18 cited

Afterpulse Measurements of R7081 Photomultipliers for the Double Chooz Experiment

Julia Haser, Florian Kaether, Conradin Langbrandtner +7

We present the results of afterpulse measurements performed as qualification test for 473 inner detector photomultipliers of the Double Chooz experiment. The measurements include t…

physics.ins-det2012★ 8 cited

The Trigger and Timing System of the Double Chooz Experiment

F. Beissel, A. Cabrera, A. Cucuanes +10

Modern precision neutrino experiments like Double Chooz require a highly efficient trigger system in order to reduce systematic uncertainties. The trigger and timing system of the…

physics.ins-det2011★ 38 cited

Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment

C. Bauer, E. Borger, R. Hofacker +9

The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu Photonics K.K. (HPK) is used in various experiments in particle and astroparticle physics. We describe the tes…