activity
20072024
most citedOn the validity of the Wigner-Seitz approximation in neutron star crust

82 citations · 412 across the 15 of their papers we have counts for

collaborators

15 papers

nucl-ex2024

Refining the nuclear mass surface with the mass of Sn

L. Nies, D. Atanasov, M. Athanasakis-Kaklamanakis +17

Mass measurements with the ISOLTRAP mass spectrometer at CERN-ISOLDE improve mass uncertainties of neutron-deficient tin isotopes towards doubly-magic Sn. The mass uncertai…

nucl-ex2024★ 10 cited

Isochronous mass spectrometry at the RIKEN Rare-RI Ring facility

D. Nagae, S. Omika, Y. Abe +28

A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted…

nucl-ex2022★ 28 cited

A new study of the and shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

S. Iimura, M. Rosenbusch, A. Takamine +34

The atomic masses of Sc, Ti, and V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been p…

nucl-ex2021★ 37 cited

First application of mass measurement with the Rare-RI Ring reveals the solar r-process abundance trend at A=122 and A=123

H. F. Li, S. Naimi, T. M. Sprouse +41

The Rare-RI Ring (R3) is a recently commissioned cyclotron-like storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Iso…

physics.ins-det2021

The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility

M. Rosenbusch, M. Wada, S. Chen +23

A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications…

physics.ins-det2020★ 14 cited

Development and operation of an electrostatic time-of-flight detector for the Rare RI storage Ring

D. Nagae, Y. Abe, S. Okada +28

An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in…

nucl-ex2019★ 26 cited

Masses of ground and isomeric states of In and configuration-dependent shell evolution in odd- indium isotopes

X. Xu, J. H. Liu, C. X. Yuan +40

We report first precision mass measurements of the isomeric and ground states of In. The determined isomeric excitation energy continues a smooth trend of o…

astro-ph.HE2018★ 1 cited

FRIB and the GW170817 Kilonova

A. Aprahamian, R. Surman, A. Frebel +45

In July 2018 an FRIB Theory Alliance program was held on the implications of GW170817 and its associated kilonova for r-process nucleosynthesis. Topics of discussion included the a…

physics.ins-det2013★ 32 cited

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

Y. Ito, P. Schury, M. Wada +8

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system cons…

nucl-ex2013★ 71 cited

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

Y. Ito, P. Schury, M. Wada +8

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, u…

nucl-ex2012★ 19 cited

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

S. Naimi, S. Nakamura, Y. Ito +8

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion…

physics.ins-det2012★ 25 cited

Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei

T. Sonoda, M. Wada, H. Tomita +21

A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam prod…

nucl-ex2011★ 38 cited

Q-Value and Half-Lives for the Double-Beta-Decay Nuclide 110Pd

D. Fink, J. Barea, D. Beck +17

The 110Pd double-beta decay Q-value was measured with the Penning-trap mass spectrometer ISOLTRAP to be Q = 2017.85(64) keV. This value shifted by 14 keV compared to the literature…

nucl-ex2009★ 29 cited

Penning trap mass measurements on (99-109)$Cd with ISOLTRAP and implications on the rp process

M. Breitenfeldt, G. Audi, D. Beck +13

Penning trap mass measurements on neutron-deficient Cd isotopes (99-109)Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertaint…

astro-ph2007★ 82 cited

On the validity of the Wigner-Seitz approximation in neutron star crust

N. Chamel, S. Naimi, E. Khan +1

The inner crust of neutron stars formed of nuclear clusters immersed in a neutron sea has been widely studied in the framework of the Wigner-Seitz approximation since the seminal w…