82 citations · 412 across the 15 of their papers we have counts for
9 papers · 1 filter
Refining the nuclear mass surface with the mass of Sn
L. Nies, D. Atanasov, M. Athanasakis-Kaklamanakis +17
Mass measurements with the ISOLTRAP mass spectrometer at CERN-ISOLDE improve mass uncertainties of neutron-deficient tin isotopes towards doubly-magic Sn. The mass uncertai…
Isochronous mass spectrometry at the RIKEN Rare-RI Ring facility
D. Nagae, S. Omika, Y. Abe +28
A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted…
A new study of the and shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI
S. Iimura, M. Rosenbusch, A. Takamine +34
The atomic masses of Sc, Ti, and V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been p…
First application of mass measurement with the Rare-RI Ring reveals the solar r-process abundance trend at A=122 and A=123
H. F. Li, S. Naimi, T. M. Sprouse +41
The Rare-RI Ring (R3) is a recently commissioned cyclotron-like storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Iso…
Masses of ground and isomeric states of In and configuration-dependent shell evolution in odd- indium isotopes
X. Xu, J. H. Liu, C. X. Yuan +40
We report first precision mass measurements of the isomeric and ground states of In. The determined isomeric excitation energy continues a smooth trend of o…
Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph
Y. Ito, P. Schury, M. Wada +8
A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, u…
An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements
S. Naimi, S. Nakamura, Y. Ito +8
For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion…
Q-Value and Half-Lives for the Double-Beta-Decay Nuclide 110Pd
D. Fink, J. Barea, D. Beck +17
The 110Pd double-beta decay Q-value was measured with the Penning-trap mass spectrometer ISOLTRAP to be Q = 2017.85(64) keV. This value shifted by 14 keV compared to the literature…
Penning trap mass measurements on (99-109)$Cd with ISOLTRAP and implications on the rp process
M. Breitenfeldt, G. Audi, D. Beck +13
Penning trap mass measurements on neutron-deficient Cd isotopes (99-109)Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertaint…