1.2k citations · 5.9k across the 45 of their papers we have counts for
8 papers · 1 filter
Demonstration of length control for a filter cavity with coherent control sidebands
Naoki Aritomi, Yuhang Zhao, Eleonora Capocasa +22
For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique an…
A vertical inertial sensor with interferometric readout
S. L. Kranzhoff, J. Lehmann, R. Kirchhoff +9
High precision interferometers such as gravitational-wave detectors require complex seismic isolation systems in order to decouple the experiment from unwanted ground motion. Impro…
Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing
Yuhang Zhao, Eleonora Capocasa, Marc Eisenmann +21
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency…
First demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory
James Lough, Emil Schreiber, Fabio Bergamin +14
Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one ki…
Huddle test measurement of a near Johnson noise limited geophone
R. Kirchhoff, C. M. Mow-Lowry, V. B. Adya +11
In this paper the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is…
Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system
G Bergmann, C M Mow-Lowry, V B Adya +13
The 10m Prototype facility at the Albert-Einstein-Institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI Seismic-…
GEO 600 and the GEO-HF upgrade program: successes and challenges
K. L. Dooley, J. R. Leong, T. Adams +25
The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science ru…
Building blocks for future detectors: Silicon test masses and 1550 nm laser light
R. Schnabel, M. Britzger, F. Brückner +10
Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room tempera…