activity
20062026
most citedFirst results from the LUX dark matter experiment at the Sanford Underground Research Facility

1.6k citations · 11.4k across the 115 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

52 papers · 1 filter

physics.ins-det2026

Commissioning and first results from the Cold Radon Emanation Facility

Emily Perry, Chamkaur Ghag, Maurits Van der Grinten +4

Radon emanation from detector materials is a critical background for next-generation rare event searches, in particular those using noble liquid targets. While highly sensitive scr…

physics.ins-det2026

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

D. S. Akerib, A. K. Al Musalhi, F. Alder +208

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions.…

physics.ins-det2026

Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments

R. R. Marcelo Gregorio, F. Dastgiri, A. Basharina-Freshville +7

Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon ema…

physics.ins-det2025

Study of few-electron backgrounds in the LUX-ZEPLIN detector

D. S. Akerib, A. K. Al Musalhi, F. Alder +204

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/--Te…

physics.ins-det2025

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +206

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, man…

physics.ins-det2025

Flow-dependent tagging of Pb decays in the LZ dark matter detector

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +205

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow stat…

physics.ins-det2024★ 11 cited

Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory

XLZD Collaboration, J. Aalbers, K. Abe +441

The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60 to 80 t capable of probing the remaining WIMP-nucleon interaction parameter…

physics.ins-det2024

Enhancing Material Screening at Boulby Underground Laboratory with XIA UltraLo-1800 Alpha Particle Detectors

Sid El Moctar Ahmed Maouloud, Anh Nguyen, XinRan Liu +9

The Boulby UnderGround Screening (BUGS) facility, located at the Boulby Underground Laboratory, has significantly advanced its material screening capabilities by installing two XIA…

physics.ins-det2024★ 7 cited

The Design, Implementation, and Performance of the LZ Calibration Systems

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +200

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) i…

physics.ins-det2024★ 1 cited

The Data Acquisition System of the LZ Dark Matter Detector: FADR

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +213

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MH…

physics.ins-det2023★ 6 cited

Ultra-Low Background Germanium Assay at the Boulby Underground Laboratory

P. R. Scovell, E. Meehan, S. M. Paling +6

As we move to an era where next generation low-background particle physics experiments begin to be designed and constructed, the ability to assay materials with high sensitivity an…

physics.ins-det2022★ 4 cited

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

LUX Collaboration, D. S. Akerib, S. Alsum +94

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability…

physics.ins-det2022★ 159 cited

A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

J. Aalbers, K. Abe, V. Aerne +591

The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leadi…

physics.ins-det2021★ 12 cited

Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe

The LUX-ZEPLIN, Collaboration, : +194

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of Xe is presented. LZ is a 10-tonne xenon time projection ch…

physics.ins-det2020★ 60 cited

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…

physics.ins-det2020★ 70 cited

Investigation of background electron emission in the LUX detector

D. S. Akerib, S. Alsum, H. M. Araújo +93

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. Whil…

physics.ins-det2020★ 43 cited

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

LUX Collaboration, D. S. Akerib, S. Alsum +94

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 20…

physics.ins-det2020★ 41 cited

Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

ZEPLIN Collaboration, D. S. Akerib, C. W. Akerlof +194

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)\,pb at a WIMP mass of 40 GeV/…

physics.ins-det2019★ 11 cited

Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data

The LUX Collaboration, D. S. Akerib, S. Alsum +96

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-pro…

physics.ins-det2019★ 16 cited

Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector

D. S. Akerib, S. Alsum, H. M. Araújo +98

We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from inje…

physics.ins-det2018★ 3 cited

LUX Trigger Efficiency

D. S. Akerib, S. Alsum, H. M. Araújo +94

The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this pap…

physics.ins-det2018★ 30 cited

Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

The LUX Collaboration, D. S. Akerib, S. Alsum +90

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…

physics.ins-det2017★ 43 cited

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

D. S. Akerib, S. Alsum, H. M. Araújo +95

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…

physics.ins-det2017★ 32 cited

Position Reconstruction in LUX

LUX Collaboration, D. S. Akerib, S. Alsum +91

The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…