3k citations · 10.1k across the 104 of their papers we have counts for
44 papers · 1 filter
Simulation and Rejection of Radon Progeny Backgrounds in nEXO
M. P. Watts, B. T. Foust, G. Richardson +97
Radon-induced backgrounds from Bi decays remain a significant challenge for liquid xenon (LXe) detectors searching for neutrinoless double beta decay (). We present a…
Cosmogenic activation in detector materials at shallow depths
Sagar S. Poudel, Lekhraj Pandey, Robert Calkins +6
The radioactive decay from long-lived radioactive isotopes produced by cosmogenic activation can be an important background in direct-detection dark matter and neutrino experiments…
An integrated online radioassay data storage and analytics tool for nEXO
R. H. M. Tsang, A. Piepke, S. Al Kharusi +157
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in…
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
SuperCDMS Collaboration, M. F. Albakry, I. Alkhatib +126
Two photo-neutron sources, YBe and SbBe, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the…
Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
A. Avasthi, T. W. Bowyer, C. Bray +31
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay () and dark m…
Opportunities for DOE National Laboratory-led QuantISED Experiments
Pete Barry, Karl Berggren, A. Baha Balantekin +24
A subset of QuantISED Sensor PIs met virtually on May 26, 2020 to discuss a response to a charge by the DOE Office of High Energy Physics. In this document, we summarize the QuantI…
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
T. Stiegler, S. Sangiorgio, J. P. Brodsky +148
nEXO is a proposed tonne-scale neutrinoless double beta decay () experiment using liquid (LXe) in a Time Projection Chamber (TPC) to read out ionization and scin…
Evaluation and mitigation of trace Pb contamination on copper surfaces
Raymond Bunker, Tsuguo Aramaki, Isaac Arnquist +5
Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availab…
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
P. Lv, G. F. Cao, L. J. Wen +148
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angula…
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
O. Njoya, T. Tsang, M. Tarka +153
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode…
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
P. Nakarmi, I. Ostrovskiy, A. K. Soma +152
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next gen…
Simulation of charge readout with segmented tiles in nEXO
Z. Li, W. R. Cen, A. Robinson +150
nEXO is a proposed experiment to search for the neutrino-less double beta decay () of Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC wil…
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
SuperCDMS Collaboration, R. Agnese, T. Aralis +95
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes ac…
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
A. Jamil, T. Ziegler, P. Hufschmidt +140
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…
nEXO Pre-Conceptual Design Report
nEXO Collaboration, S. Al Kharusi, A. Alamre +171
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…
Initial Results from the Majorana Demonstrator
T. S. Caldwell, N. Abgrall, S. I. Alvis +69
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge with the goal of establishing the required b…
Characterization of an Ionization Readout Tile for nEXO
nEXO Collaboration, M. Jewell, A. Schubert +142
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…
The Majorana Demonstrator calibration system
N. Abgrall, I. J. Arnquist, F. T. Avignone +64
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with…
Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors
J. Gruszko, N. Abgrall, I. J. Arnquist +64
The Majorana Demonstrator searches for neutrinoless double-beta decay of Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that…
Projected Sensitivity of the SuperCDMS SNOLAB experiment
R. Agnese, A. J. Anderson, T. Aramaki +93
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c) particles that may constitute dark matter by using cryogenic detectors o…
The Majorana Demonstrator search for neutrinoless double beta decay
C. Cuesta, M. Buuck, J. A. Detwiler +64
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76)…
High voltage testing for the MAJORANA Demonstrator
N. Abgrall, I. J. Arnquist, F. T. Avignone +70
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-…
A Low-noise Germanium Ionization Spectrometer for Low-background Science
Craig E. Aalseth, Juan I. Collar, Jim Colaresi +7
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The d…
Development of a low-level Ar-37 calibration standard
R. M. Williams, C. E. Aalseth, T. W. Bowyer +16
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive…