480 citations · 1.6k across the 32 of their papers we have counts for
10 papers · 1 filter
Design and test for the CEPC muon subdetector based on extruded scintillator and SiPM
Hongyu Zhang, Xiyang Wang, Weihu Ma +7
A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the ` and detector (KLM)' of the Bel…
Light yield and field dependence measurement in PandaX-II dual-phase xenon detector
Zhou Huang, Abdusalam Abdukerim, Zihao Bo +76
The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle…
Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
Zhicheng Qian, Lin Si, Abdusalam Abdukerim +76
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technolo…
A 500 MS/s waveform digitizer for PandaX dark matter experiments
Changda He, Jianglai Liu, Xiangxiang Ren +8
Waveform digitizers are key readout instruments in particle physics experiments. In this paper, we present a waveform digitizer for the PandaX dark matter experiments. It supports…
Readout electronics and data acquisition system of PandaX-4T experiment
Jijun Yang, Xun Chen, Changda He +11
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid…
Horizontal Position Reconstruction in PandaX-II
Dan Zhang, Andi Tan, Abdusalam Abdukerim +69
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertex…
Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
Binbin Yan, Abdusalam Abdukerim, Wei Chen +63
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear…
An improved design of the readout base board of the photomultiplier tube for future PandaX dark matter experiments
Qibin Zheng, Yanlin Huang, Di Huang +7
The PandaX project consists of a series of xenon-based experiments that are used to search for dark matter (DM) particles and to study the fundamental properties of neutrinos. The…
Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65
We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…
Dark matter direct search sensitivity of the PandaX-4T experiment
Hongguang Zhang, Abdusalam Abdukerim, Xun Chen +57
The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulat…