most citedThermoelectric Sensors as Microcalorimeter Load

32 citations · 111 across the 11 of their papers we have counts for

collaborators
Showing 2021Show all

9 papers · 1 filter

physics.ins-det2021★ 32 cited

Thermoelectric Sensors as Microcalorimeter Load

L. Brunetti, L. Oberto, E. Vremera

Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be le…

physics.ins-det2021★ 12 cited

On Coaxial Microcalorimeter Calibration

L. Brunetti, L. Oberto

Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is…

physics.ins-det2021★ 1 cited

Improvement of primary power standard through international comparison feedback

Luciano Brunetti, Luca Oberto, Marco Sellone

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurem…

physics.ins-det2021★ 14 cited

Alternative Procedures in Realizing of the High Frequency Power Standards with Microcalorimeter and Thermoelectric Power Sensors

Emil Vremera, Luciano Brunetti, Luca Oberto +1

The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial…

physics.ins-det2021★ 17 cited

Comparison Among Coaxial Microcalorimeter Models

L. Brunetti, L. Oberto, M. Sellone +1

Thermoelectric power sensors used as power transfer standards are promising devices for further enhancements of the microcalorimetric technique in the high frequency field. A coaxi…

physics.ins-det2021★ 17 cited

Comparison between Thermoelectric and Bolometric Microwave Power Standards

Luciano Brunetti, Luca Oberto, Marco Sellone +1

In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have…

physics.ins-det2021★ 3 cited

Improvements on INRIM Coaxial Microcalorimeter and Outcome of a Model Comparison

Luciano Brunetti, Luca Oberto, Marco Sellone +2

This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency…

physics.app-ph2021★ 6 cited

Uncertainty Analysis for Material Measurements Using the Vector Network Analyzer

Nosherwan Shoaib, Marco Sellone, Luciano Brunetti +1

This paper presents the characterization measurements and related uncertainty evaluation of a nonmagnetic material using the Vector Network Analyzer (VNA) at microwave frequencies.…

physics.ins-det2021★ 4 cited

RF/MW power standard realization without unitary efficiency assumption at dc/LF

Luca Oberto, Luciano Brunetti

Thermoelectric power sensors are widely used in commercial power meters at RF and microwaves, due to their superior robustness, stability, and accuracy if compared with other types…