23 citations · 79 across the 13 of their papers we have counts for
14 papers
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area
A. Pandey, K. Gnanvo, B. Kross +60
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…
Hybrid MCP-PMT characterisation on a testbeam with Cherenkov setup
G. Romolini, J. Alozy, R. Ballabriga +12
A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection…
Challenges and strategies in verification of FastRICH ASIC for the LHCb RICH detector
M. Lupi, R. Ballabriga, F. N. Bandi +13
The FastRICH ASIC provides high-precision, triggerless readout for the LS3 Enhancements and Upgrades II of the LHCb RICH detector. The demands of continuous data acquisition and va…
Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond
D. Mazzanti, S. Gomez, J. Mauricio +19
This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors…
Timepix3: single-pixel multi-hit energy-measurement behavior
Hubertus Bromberger, David Pennicard, Rafael Ballabriga +2
The event-driven hybrid-pixel detector readout chip, Timepix3, has the ability to simultaneously measure the time of an event on the nanosecond timescale and the energy deposited i…
High-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities
Viros Sriskaran, Jerome Alozy, Rafael Ballabriga +10
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be…
Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications
Zhehui Wang, Andrew F. T. Leong, Angelo Dragone +25
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics,…
Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector
Florian Beißer, Dennis Haag, Rafael Ballabriga +27
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix dete…
Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode technology demonstrator CLICTD
Katharina Dort, Rafael Ballabriga, Justus Braach +12
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabric…
Timing performance of the Timepix4 front-end
K. Heijhoff, K. Akiba, R. Ballabriga +7
A characterisation of the Timepix4 pixel front-end with a strong focus on timing performance is presented. Externally generated test pulses were used to probe the per-pixel time-to…
Transient Monte Carlo Simulations for the Optimisation and Characterisation of Monolithic Silicon Sensors
Rafael Ballabriga, Justus Braach, Eric Buschmann +12
An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite e…
Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector
Dennis Haag, Sebastian Schmidt, Patrick Hufschmidt +13
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal…
Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement
R. Ballabriga, E. Buschmann, M. Campbell +15
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obta…
Sub-100 nanosecond temporally resolved imaging with the Medipix3 direct electron detector
Gary W. Paterson, Raymond J. Lamb, Rafael Ballabriga +3
Detector developments are currently enabling new capabilities in the field of transmission electron microscopy (TEM). We have investigated the limits of a hybrid pixel detector, Me…