1.6k citations · 6k across the 48 of their papers we have counts for
26 papers · 1 filter
Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector
D. S. Akerib, A. K. Al Musalhi, F. Alder +208
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions.…
Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source
J. Aalbers, D. S. Akerib, A. K. Al Musalhi +206
The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, man…
Flow-dependent tagging of Pb decays in the LZ dark matter detector
J. Aalbers, D. S. Akerib, A. K. Al Musalhi +205
The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow stat…
Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory
XLZD Collaboration, J. Aalbers, K. Abe +441
The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60 to 80 t capable of probing the remaining WIMP-nucleon interaction parameter…
The Design, Implementation, and Performance of the LZ Calibration Systems
J. Aalbers, D. S. Akerib, A. K. Al Musalhi +200
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) i…
The Data Acquisition System of the LZ Dark Matter Detector: FADR
J. Aalbers, D. S. Akerib, A. K. Al Musalhi +213
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MH…
Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector
C. S. Amarasinghe, R. Coronel, D. Q. Huang +5
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon exp…
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
LUX Collaboration, D. S. Akerib, S. Alsum +94
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability…
Feasibility Study to use Neutron Capture for an Ultra-low Energy Nuclear-recoil Calibration in Liquid Xenon
C. S. Amarasinghe, R. Coronel, D. Q. Huang +5
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is opt…
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
The LUX-ZEPLIN, Collaboration, : +194
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of Xe is presented. LZ is a 10-tonne xenon time projection ch…
Performance Study of Charcoal-based Radon Reduction Systems for Ultraclean Rare Event Detectors
M. Arthurs, D. Q. Huang, C. Amarasinghe +2
The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event sea…
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
Investigation of background electron emission in the LUX detector
D. S. Akerib, S. Alsum, H. M. Araújo +93
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. Whil…
Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
The LUX Collaboration, D. S. Akerib, S. Alsum +96
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-pro…
LUX Trigger Efficiency
D. S. Akerib, S. Alsum, H. M. Araújo +94
The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this pap…
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
The LUX Collaboration, D. S. Akerib, S. Alsum +90
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
Position Reconstruction in LUX
LUX Collaboration, D. S. Akerib, S. Alsum +91
The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
D. S. Akerib, S. Alsum, H. M. Araújo +98
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…
Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
J. R. Verbus, C. A. Rhyne, D. C. Malling +12
We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galact…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Chromatographic separation of radioactive noble gases from xenon
LUX Collaboration, D. S. Akerib, H. M. Araújo +96
The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…