613 citations · 2.8k across the 54 of their papers we have counts for
25 papers · 1 filter
The nEXO Radioassay Program
R. MacLellan, P. Acharya, B. Aharmim +148
Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design…
Novel High-Radiopurity Doped Amorphous Silicon Resistors for Low-Background Detectors
A. Anker, P. C. Rowson, K. Skarpaas +9
We present the results of a study of lightly doped amorphous silicon used as a resistive medium for high-radiopurity resistors in nuclear and particle physics research instrumentat…
Characterization of CRYO ASIC for charge readout in the nEXO experiment
Z. Li, M. Yu, E. Angelico +141
nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). T…
Removal of spallation-induced tritium from silicon through diffusion
R. Saldanha, D. Reading, P. E. Warwick +5
Tritium, predominantly produced through spallation reactions caused by cosmic ray interactions, is a significant radioactive background for silicon-based rare event detection exper…
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
nEXO Collaboration, A. Anker, P. A. Breur +138
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a signif…
Directionality of nuclear recoils in a liquid argon time projection chamber
20k Collaboration, P. Agnes, I. Ahmad +264
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the W…
Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches
20k Collaboration
The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori…
Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors
Carl Eric Dahl, Roxanne Guenette, Jennifer L. Raaf +39
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in co…
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
P. Agnes, I. Ahmad, S. Albergo +296
Dark matter lighter than 10 GeV/c encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50…
Characterization of the scintillation time response of liquid argon detectors for dark matter search
P. Agnes, S. De Cecco, A. Fan +17
The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejecti…
Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
The DarkSide collaboration, P. Agnes, I. F. M. Albuquerque +136
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c mass range. The technique, b…
A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber
50 Collaboration, P. Agnes, I. F. M. Albuquerque +135
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to prob…
Separating Ar from Ar by cryogenic distillation with Aria for dark matter searches
DarkSide Collaboration, P. Agnes, S. Albergo +309
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft a…
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim +312
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle…
Absolute Calibration of the DANCE Thermal Neutron Beam using Sodium Activation
V. Fischer, L. Pagani, L. Pickard +6
The measurement of the neutron capture cross-section as a function of energy in the thermal range requires a precise knowledge of the absolute neutron flux. In this paper a new met…
Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC
P. Agnes, I. F. M. Albuquerque, T. Alexander +163
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift elec…
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
C. E. Aalseth, F. Acerbi, P. Agnes +282
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a tw…
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque +177
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon a…
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque +147
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP intera…
Cryogenic Characterization of FBK RGB-HD SiPMs
C. E. Aalseth, F. Acerbi, P. Agnes +268
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matt…
Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon
P. Agnes, I. F. M. Albuquerque, T. Alexander +158
Measurements were made of scintillation light yield of alpha particles from the Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield…
CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment
P. Agnes, I. F. M. Albuquerque, T. Alexander +162
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS…
The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors
P. Agnes, L. Agostino, I. F. M. Albuquerque +155
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for t…
The veto system of the DarkSide-50 experiment
The DarkSide Collaboration, P. Agnes, L. Agostino +158
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils th…