High-energy proton induced damage in Lead Tungstate calorimeter crystals
arXiv:physics/0412085 · doi:10.1016/j.nima.2005.01.304
Abstract
Eight production quality PbWO4 crystals of CMS have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4E13cm-2. The damage recovery in these crystals has been followed for over a year. Comparative irradiations with 60Co photons have been performed on seven other crystals using a dose rate of 1 kGy/h. In proton irradiated crystals the light transmission band-edge shifts and the induced absorption length is proportional to the inverse of the 4th power of the wavelength. In gamma-irradiated crystals the band-edge does not shift but formation of absorption bands is seen clearly. The absorption length induced by gamma-radiation in crystals verified to have excellent radiation hardness, saturates at a level below 0.5 m-1. In the case of protons, we observe no correlation with the pre-characterised radiation hardness of the crystals and the induced absorption increases linearly with fluence. After a fluence of 5E13 cm-2, an induced absorption length of approx. 15m-1 is seen with no sign of saturation. These observations provide strong evidence that high-energy protons create damage that cannot be reproduced with gamma-irradiation. However, these hadronic effects manifest themselves only at integral fluences well beyond 1E12cm-2 and most likely would escape undetected at lower fluences. A large fraction of the damage, both in proton- and gamma-irradiated crystals, is either stable or recovers very slowly.
Submitted to Elsevier Science on November 23rd, 2004
References in corpus (4)
Cited by in corpus (13)
- Performance of photon reconstruction and identification with the CMS detector in proton-proton collisions at sqrt(s) = 8 TeV
- A study of high-energy proton induced damage in Cerium Fluoride in comparison with measurements in Lead Tungstate calorimeter crystals
- A visualization of the damage in Lead Tungstate calorimeter crystals after exposure to high-energy hadrons
- High-energy proton induced damage study of scintillation light output from PbWO4 calorimeter crystals
- Results on damage induced by high-energy protons in LYSO calorimeter crystals
- Comparison between high-energy proton and charged pion induced damage in Lead Tungstate calorimeter crystals
- Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
- Proof-of-principle of a new geometry for sampling calorimetry using inorganic scintillator plates
- Studies of the effect of charged hadrons on lead tungstate crystals
- Performance studies of scintillating ceramic samples exposed to ionizing radiation
- A FLUKA study towards predicting hadron-specific damage due to high-energy hadrons in inorganic crystals for calorimetry
- Proton induced damage in LFS-3 and LFS-8 scintillating crystals
- Predicting hadron-specific damage from fast hadrons in crystals for calorimetry