Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation
arXiv:physics/0312063 · doi:10.1016/j.nima.2004.04.231
Abstract
Studies of the radiation hardness of lead tungstate crystals produced by the Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of Ceramics in China have been carried out at IHEP, Protvino. The crystals were irradiated by a 40-GeV pion beam. After full recovery, the same crystals were irradiated using a -ray source. The dose rate profiles along the crystal length were observed to be quite similar. We compare the effects of the two types of radiation on the crystals light output.
arXiv comment10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical changes
References in corpus (3)
Cited by in corpus (7)
- High-energy proton induced damage in Lead Tungstate calorimeter crystals
- First study of radiation hardness of lead tungstate crystals at low temperatures
- High-energy proton induced damage study of scintillation light output from PbWO4 calorimeter crystals
- Comparison between high-energy proton and charged pion induced damage in Lead Tungstate calorimeter crystals
- Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
- Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
- Studies of the effect of charged hadrons on lead tungstate crystals