Results on damage induced by high-energy protons in LYSO calorimeter crystals
arXiv:1309.3872 · doi:10.1016/j.nima.2014.02.003
Abstract
Lutetium-Yttrium Orthosilicate doped with Cerium (LYSO:Ce), as a bright scintillating crystal, is a candidate for calorimetry applications in strong ionizing-radiation fields and large high-energy hadron fluences as are expected at the CERN Large Hadron Collider after the planned High-Luminosity upgrade. There, proton-proton collisions will produce fast hadron fluences up to ~5E14/cm^2 in the large-rapidity regions of the calorimeters. The performance of LYSO:Ce has been investigated, after exposure to different fluences of 24 GeV/c protons. Measured changes in optical transmission as a function of proton fluence are presented, and the evolution over time due to spontaneous recovery at room temperature is studied. The activation of materials will also be an issue in the described environment. Studies of the ambient dose induced by LYSO and its evolution with time, in comparison with other scintillating crystals, have also been performed through measurements and FLUKA simulations.
arXiv comment10 pages, 9 figures, submitted to Elsevier for publication in Nucl. Instr. Meth. in Phys. Research A
References in corpus (8)
- Performance and Operation of the CMS Electromagnetic Calorimeter
- High-energy proton induced damage in Lead Tungstate calorimeter crystals
- A study of high-energy proton induced damage in Cerium Fluoride in comparison with measurements in Lead Tungstate calorimeter crystals
- A visualization of the damage in Lead Tungstate calorimeter crystals after exposure to high-energy hadrons
- High-energy proton induced damage study of scintillation light output from PbWO4 calorimeter crystals
- Comparison between high-energy proton and charged pion induced damage in Lead Tungstate calorimeter crystals
- Crystals for high-energy calorimetry in extreme environments
- Studies of the effect of charged hadrons on lead tungstate crystals
Cited by in corpus (8)
- Measurement of time resolution of the Mu2e LYSO calorimeter prototype
- Proof-of-principle of a new geometry for sampling calorimetry using inorganic scintillator plates
- Precision timing detectors
- Cerium-Doped Fused-Silica Fibers as Wavelength Shifters
- Evolution studies of the CMS ECAL endcap response and upgrade design options for High-Luminosity LHC
- A FLUKA study towards predicting hadron-specific damage due to high-energy hadrons in inorganic crystals for calorimetry
- Determination of Position Resolution for LYSO Scintillation Crystals using Geant4 Monte Carlo Code
- Predicting hadron-specific damage from fast hadrons in crystals for calorimetry