Measurement of radon concentrations at Super-Kamiokande
arXiv:hep-ex/9903006 · doi:10.1016/S0370-2693(99)00311-1
Abstract
Radioactivity from radon is a major background for observing solar neutrinos at Super-Kamiokande. In this paper, we describe the measurement of radon concentrations at Super-Kamiokande, the method of radon reduction, and the radon monitoring system. The measurement shows that the current low-energy event rate between 5.0 MeV and 6.5 MeV implies a radon concentration in the Super-Kamiokande water of less than 1.4 mBq/m.
11 pages, 4 figures
References in corpus (1)
Cited by in corpus (8)
- Solar neutrino measurements in Super-Kamiokande-I
- Solar neutrino measurements in Super-Kamiokande-II
- DUNE as the Next-Generation Solar Neutrino Experiment
- Developing the MeV potential of DUNE: Detailed considerations of muon-induced spallation and other backgrounds
- Measurement of Radon Concentration in Super-Kamiokande's Buffer Gas
- Sensitivity of Super-Kamiokande with Gadolinium to Low Energy Anti-neutrinos from Pre-supernova Emission
- Measurement of the radon concentration in purified water in the Super-Kamiokande IV detector
- Study of radon removal performance of silver-ion exchanged zeolite from air for underground experiments