Abstract
The QND intracavity topologies of gravitational-wave detectors proposed several years ago allow, in principle, to obtain sensitivity significantly better than the Standard Quantum Limit using relatively small anount of optical pumping power. In this article we consider an improved more ``practical'' version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the Discrete Sampling Variation Measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.
27 pages, 6 figures
References in corpus (8)
- Scaling law in signal recycled laser-interferometer gravitational-wave detectors
- Squeezed-input, optical-spring, signal-recycled gravitational-wave detectors
- Practical speed meter designs for QND gravitational-wave interferometers
- Second generation instruments for the Laser Interferometer Gravitational Wave Observatory (LIGO)
- Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector
- Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers
- Sensitivity limitations in optical speed meter topology of gravitational-wave antennae
- Low pumping energy mode of the "optical bars''/"optical lever" topologies of gravitational-wave antennae
Cited by in corpus (10)
- Quantum Measurement Theory in Gravitational-Wave Detectors
- Triple Michelson Interferometer for a Third-Generation Gravitational Wave Detector
- QND measurements for future gravitational-wave detectors
- Quantum state preparation and macroscopic entanglement in gravitational-wave detectors
- Anomalous dynamic back-action in interferometers
- Engineering the Optical Spring via Intra-Cavity Optical-Parametric Amplification
- Displacement-noise-free gravitational-wave detection with a single Fabry-Perot cavity: a toy model
- Sensitivity below the standard quantum limit in gravitational wave detectors with Michelson-Fabry-Perot readout
- Quantum variational measurement and the "optical lever" intracavity topology of gravitational-wave detectors