Quantum variational measurement and the "optical lever" intracavity topology of gravitational-wave detectors
arXiv:gr-qc/0607028 · doi:10.1103/PhysRevD.75.082003
Abstract
The intracavity topologies of laser gravitational-wave detectors are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). The most challenging element of the intracavity topologies is the \emph{local meter} which has to monitor position of a small ( gram) local mirror and which precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter back-action noise and measurement noise is introduced, which allows to eliminate the back-action noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment about 10 meter long filter cavity can be used to obtain sensitivity approximately times better than the SQL. For future QND gravitational-wave detectors with sensitivity about ten times better than the SQL, the filter cavity length should be within kilometer range.
arXiv comment24 pages, 10 figures, 3 tables
References in corpus (17)
- Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
- Quantum noise in second generation, signal-recycled laser interferometric gravitational-wave detectors
- Coherent control of vacuum squeezing in the Gravitational-Wave Detection Band
- Quantum limits in interferometric measurements
- Squeezing in the audio gravitational wave detection band
- Signal recycled laser-interferometer gravitational-wave detectors as optical springs
- Scaling law in signal recycled laser-interferometer gravitational-wave detectors
- A squeezed state source using radiation pressure induced rigidity
- Thermodynamical fluctuations in optical mirror coatings
- Beating quantum limits in optomechanical sensor by cavity detuning
- The noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization
- Reducing the mirrors coating noise in laser gravitational-wave antennae by means of double mirrors
- The "optical lever" intracavity readout scheme for gravitational-wave antennae
- Sub-SQL Sensitivity via Optical Rigidity in Advanced LIGO Interferometer with Optical Losses
- Low pumping energy mode of the "optical bars''/"optical lever" topologies of gravitational-wave antennae
- To the practical design of the optical lever intracavity topology of gravitational-wave detectors
- Squeezed-field injection for gravitational wave interferometers
Cited by in corpus (5)
- LIGOs Quantum Response to Squeezed States
- Quantum variational measurement in the next generation gravitational-wave detectors
- Increasing future gravitational-wave detectors sensitivity by means of amplitude filter cavities and quantum entanglement
- Displacement-noise-free gravitational-wave detection with a single Fabry-Perot cavity: a toy model
- Pass-through Mach-Zehnder topologies for macroscopic quantum measurements