Frequency-dependent rigidity in large-scale interferometric gravitational-wave detectors
arXiv:gr-qc/0107084 · doi:10.1016/S0375-9601(01)00550-3
Abstract
Electromagnetic rigidity which exists in large-scale optical resonators if pumping frequency is detuned from the eigenfrequency of resonator have sophisticated spectral dependence which allows to obtain sensitivity better than the Standard Quantum Limits both for the free test mass and the harmonic oscillator.
11 pages, 6 figures, corrected typos
Cited by in corpus (34)
- Quantum Measurement Theory in Gravitational-Wave Detectors
- Optomechanical trapping and cooling of partially transparent mirrors
- Trapping and Cooling a mirror to its quantum mechanical ground state
- Scaling law in signal recycled laser-interferometer gravitational-wave detectors
- Advanced quantum techniques for future gravitational-wave detectors
- An analysis of a QND speed-meter interferometer
- QND measurements for future gravitational-wave detectors
- High Q mg-scale monolithic pendulum for quantum-limited gravity measurements
- The Response of Test Masses to Gravitational Waves in the Coordinates of a Local Observer
- Anomalous dynamic back-action in interferometers
- The "optical lever" intracavity readout scheme for gravitational-wave antennae
- Negative optical inertia for enhancing the sensitivity of future gravitational-wave detectors
- Engineering the Optical Spring via Intra-Cavity Optical-Parametric Amplification
- Laser-interferometer gravitational-wave optical-spring detectors
- Sub-SQL Sensitivity via Optical Rigidity in Advanced LIGO Interferometer with Optical Losses
- Low pumping energy mode of the "optical bars''/"optical lever" topologies of gravitational-wave antennae
- To the practical design of the optical lever intracavity topology of gravitational-wave detectors
- Increasing the sensitivity of future gravitational-wave detectors with double squeezed-input
- Optimizing the regimes of Advanced LIGO gravitational wave detector for multiple source types
- Interaction of plane gravitational waves with a Fabry-Perot cavity in the local Lorentz frame
- On sensitivity limitations of a dichromatic optical detection of a classical mechanical force
- Dissipative coupling, dispersive coupling and their combination in the cavity-less opto-mechanical systems
- Displacement-noise-free gravitational-wave detection with a single Fabry-Perot cavity: a toy model
- Broadband Dichromatic Variational Measurement
- Stable optical spring in aLIGO detector with unbalanced arms and in Michelson-Sagnac interferometer
- Combination of dissipative and dispersive coupling in the cavity optomechanical systems
- Paired carriers as a way to reduce quantum noise of multi-carrier gravitational-wave detectors
- Stable Optical Rigidity Based on Dissipative Coupling
- Stable double-resonance optical spring in laser gravitational-wave detectors
- Broadband Coherent Multidimensional Variational Measurement
- Sensitivity of laser gravitational-wave detectors with stable double-pumped optical spring
- Squeezing of optomechanical modes in detuned Fabry-Perot interferometer
- Trade-off between quantum and thermal fluctuations in mirror coatings yields improved sensitivity of gravitational-wave interferometers
- Broadband Back Action Cancellation in a Dichromatic Variational Measurement