Negative optical inertia for enhancing the sensitivity of future gravitational-wave detectors
arXiv:1010.1124 · doi:10.1103/PhysRevD.83.062003
Abstract
We consider enhancing the sensitivity of future gravitational-wave detectors by using double optical spring. When the power, detuning and bandwidth of the two carriers are chosen appropriately, the effect of the double optical spring can be described as a "negative inertia", which cancels the positive inertia of the test masses and thus increases their response to gravitational waves. This allows us to surpass the free-mass Standard Quantum Limit (SQL) over a broad frequency band, through signal amplification, rather than noise cancelation, which has been the case for all broadband SQL-beating schemes so far considered for gravitational-wave detectors. The merit of such signal amplification schemes lies in the fact that they are less susceptible to optical losses than noise cancelation schemes. We show that it is feasible to demonstrate such an effect with the {\it Gingin High Optical Power Test Facility}, and it can eventually be implemented in future advanced GW detectors.
arXiv comment7 pages, 3 figures
References in corpus (20)
- Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
- Nanomechanical motion measured with precision beyond the standard quantum limit
- An all-optical trap for a gram-scale mirror
- Quantum noise in second generation, signal-recycled laser interferometric gravitational-wave detectors
- Stable Operation of a 300-m Laser Interferometer with Sufficient Sensitivity to Detect Gravitational-Wave Events within our Galaxy
- Signal recycled laser-interferometer gravitational-wave detectors as optical springs
- A Xylophone Configuration for a third Generation Gravitational Wave Detector
- The path to the enhanced and advanced LIGO gravitational-wave detectors
- Scaling law in signal recycled laser-interferometer gravitational-wave detectors
- Practical speed meter designs for QND gravitational-wave interferometers
- Second generation instruments for the Laser Interferometer Gravitational Wave Observatory (LIGO)
- Dual-Resonator Speed Meter for a Free Test Mass
- Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector
- Beating quantum limits in optomechanical sensor by cavity detuning
- The noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization
- Frequency-dependent rigidity in large-scale interferometric gravitational-wave detectors
- QND measurements for future gravitational-wave detectors
- Double optical spring enhancement for gravitational wave detectors
- Sub-SQL Sensitivity via Optical Rigidity in Advanced LIGO Interferometer with Optical Losses
- Sensitivity below the standard quantum limit in gravitational wave detectors with Michelson-Fabry-Perot readout
Cited by in corpus (14)
- Macroscopic Quantum Mechanics: Theory and Experimental Concepts of Optomechanics
- Quantum Measurement Theory in Gravitational-Wave Detectors
- Advanced quantum techniques for future gravitational-wave detectors
- Anomalous dynamic back-action in interferometers
- Engineering the Optical Spring via Intra-Cavity Optical-Parametric Amplification
- Multi-color Cavity Metrology
- A New Bound on Excess Frequency Noise in Second Harmonic Generation in PPKTP at the 10^-19 Level
- Boosting the sensitivity of high frequency gravitational wave detectors by PT-symmetry
- Towards thermal noise free optomechanics
- Paired carriers as a way to reduce quantum noise of multi-carrier gravitational-wave detectors
- Sensitivity of laser gravitational-wave detectors with stable double-pumped optical spring
- Back-Action Evading Measurement in Gravitational Wave Detectors to Overcome Standard Quantum Limit, Using Negative Radiation Pressure
- Trade-off between quantum and thermal fluctuations in mirror coatings yields improved sensitivity of gravitational-wave interferometers
- Coherent noise cancellation in optomechanical system with double optical modes