The yield of air fluorescence induced by electrons
arXiv:astro-ph/0604498 · doi:10.1016/j.astropartphys.2006.06.006
Abstract
The fluorescence yield for dry air and pure nitrogen excited by electrons is calculated using a combination of well-established molecular properties and experimental data of the involved cross sections. Particular attention has been paid to the role of secondary electrons from ionization processes. At high pressure and high energy, observed fluorescence turns out to be proportional to the ionization cross section which follows the Born-Bethe law. Predictions on fluorescence yields in a very wide interval of electron energies (eV - GeV) and pressures (1 and 1013 hPa) as expected from laboratory measurements are presented. Experimental results at energies over 1 MeV are in very good agreement with our calculations for pure nitrogen while discrepancies of about 20% are found for dry air, very likely associated to uncertainties in the available data on quenching cross sections. The relationship between fluorescence emission, stopping power and deposited energy is discussed.
27 pages, 12 figures, 64 references. Accepted in Astroparticle Physics
References in corpus (7)
- Energy determination in the Akeno Giant Air Shower Array experiment
- Measurement of the Flux of Ultrahigh Energy Cosmic Rays from Monocular Observations by the High Resolution Fly's Eye Experiment
- New measurement on photon yields from air and the application to the energy estimation of primary cosmic rays
- Observing the Ultrahigh Energy Universe with OWL Eyes
- Photon yields from nitrogen gas and dry air excited by electrons
- Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors
- Impact of Varying Atmospheric Profiles on Extensive Air Shower Observation: Fluorescence Light Emission and Energy Reconstruction
Cited by in corpus (9)
- Measurement of the pressure dependence of air fluorescence emission induced by electrons
- Air Fluorescence Relevant for Cosmic-Ray Detection - Summary of the 5th Fluorescence Workshop, El Escorial 2007
- Air fluorescence measurements in the spectral range 300-420 nm using a 28.5 GeV electron beam
- Absolute measurement of the nitrogen fluorescence yield in air between 300 and 430 nm
- On the absolute value of the air-fluorescence yield
- Comparison of available measurements of the absolute fluorescence yield
- Improved model for the analysis of air fluorescence induced by electrons
- Effects of the Energy Error Distribution of Fluorescence Telescopes on the UHECR energy spectrum
- Measurement of air fluorescence light yield induced by an electromagnetic shower