Comparison of available measurements of the absolute fluorescence yield
arXiv:1004.3971 · doi:10.1016/j.astropartphys.2010.06.007
Abstract
The uncertainty in the absolute value of the fluorescence yield is still one of the main contributions to the total error in the reconstruction of the primary energy of ultra-energetic air showers using the fluorescence technique. A significant number of experimental values of the fluorescence yield have been published in the last years, however reported results are given very often in different units (photons/MeV or photons/m) and for different wavelength intervals. In this work we present a comparison of available results normalized to its value in photons/MeV for the 337 nm band at 800 hPa and 293 K. The conversion of photons/m to photons/MeV requires an accurate determination of the energy deposited by the electrons in the field of view of the experimental setup. We have calculated the energy deposition for each experiment by means of a detailed Monte Carlo simulation including when possible the geometrical details of the particular setup. Our predictions on deposited energy, as well as on some geometrical factors, have been compared with those reported by the authors of the corresponding experiments and possible corrections to the fluorescence yields are proposed.
arXiv comment29 pages, 5 figures Revised version submitted to Astroparticle Physics
References in corpus (16)
- The Jem-Euso Mission
- New measurement on photon yields from air and the application to the energy estimation of primary cosmic rays
- Measurement of the pressure dependence of air fluorescence emission induced by electrons
- Photon yields from nitrogen gas and dry air excited by electrons
- Air Fluorescence Relevant for Cosmic-Ray Detection - Summary of the 5th Fluorescence Workshop, El Escorial 2007
- Spectral resolved Measurement of the Nitrogen Fluorescence Emissions in Air induced by Electrons
- Air fluorescence measurements in the spectral range 300-420 nm using a 28.5 GeV electron beam
- Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments
- Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors
- Absolute measurement of the nitrogen fluorescence yield in air between 300 and 430 nm
- The yield of air fluorescence induced by electrons
- A novel method for the absolute fluorescence yield measurement by AIRFLY
- Comparison of air fluorescence and ionization measurements of E.M. shower depth profiles: test of a UHECR detector technique
- Observing Ultra High Energy Cosmic Particles from Space: SEUSO, the Super Extreme Universe Space Observatory Mission
- Improved model for the analysis of air fluorescence induced by electrons
- The Air-Fluorescence Yield
Cited by in corpus (6)
- Precise measurement of the absolute fluorescence yield of the 337 nm band in atmospheric gases
- On the absolute value of the air-fluorescence yield
- Nitrogen fluorescence in air for observing extensive air showers
- The impact of the air-fluorescence yield on the reconstructed shower parameters of ultra-high energy cosmic rays
- Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases
- On the energy deposition by electrons in air and the accurate determination of the air-fluorescence yield