Studying AC-LGAD strip sensors from laser and testbeam measurements
arXiv:2511.14095 · doi:10.1088/1748-0221/21/02/P02006
Abstract
This paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate RD efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.
References in corpus (3)
- Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data
- Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control
- Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam