Readout noise of digital frequency multiplexed TES detectors for CUPID
arXiv:2509.07223 · doi:10.1109/TNS.2025.3638275
Abstract
Superconducting transition-edge sensor (TES) detectors have been the standard in Cosmic Microwave Background experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this paper we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. We find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.
arXiv comment8 pages, 8 figures. Presented at the IEEE SORMA West 2025, accepted for publication in IEEE Transactions on Nuclear Science
References in corpus (15)
- SPT-3G: A Next-Generation Cosmic Microwave Background Polarization Experiment on the South Pole Telescope
- The POLARBEAR-2 and the Simons Array Experiment
- Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic Microwave Background Measurements
- SPTpol: an instrument for CMB polarization measurements with the South Pole Telescope
- Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- Precise measurement of decay of Mo with the CUPID-Mo detection technology
- Improved Performance of TES Bolometers using Digital Feedback
- The front-end electronics system for the CUORE experiment
- The Simons Observatory microwave SQUID multiplexing detector module design
- Year two instrument status of the SPT-3G cosmic microwave background receiver
- Digital frequency domain multiplexing readout electronics for the next generation of millimeter telescopes
- CUPID, the CUORE Upgrade with Particle IDentification
- Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model
- Low Noise Frequency Domain Multiplexing of TES Bolometers using Sub-kelvin SQUIDs