Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions
arXiv:2501.07758 · doi:10.1016/j.nima.2025.170782
Abstract
The advent of both multi-messenger and time-domain astrophysics over the last decade has seen a large interest in the development of small-scale, cheap, and robust gamma-ray detectors. This has been further encouraged by the availability of CubeSat platforms. Of particular interest are detectors capable of producing spectral and localization measurements of X and gamma-ray transients to allow for accurate follow-up measurements at different wavelengths. A vast number of the instruments developed for such purposes in the last years use a combination of scintillators and Silicon Photomultipliers (SiPMs) for photon detection. Here, we present the design, performance, and space qualification of a readout system capable of reading out 64 SiPM channels. This low-power and low-cost system was originally designed for the POLAR-2 mission, a large scale gamma-ray polarimeter. However, its flexible design makes it equally suitable for use on various CubeSat missions. The system was found to perform well when reading out both plastic and high Z scintillators using a total of 1.8~W. The space qualified design furthermore relies on commercial off-the-shelf components, thereby also removing most international export issues. In this paper, we will present the overall design, the performance of the electronics, its performance when reading out various scintillators and the successful space-qualification of this design.
Accepted for publication in NIM
References in corpus (11)
- Gravitational Waves and Gamma-rays from a Binary Neutron Star Merger: GW170817 and GRB 170817A
- Design and construction of the POLAR detector
- The peak-flux of GRB 221009A measured with GRBAlpha
- A compact instrument for gamma-ray burst detection on a CubeSat platform I: Design drivers and expected performance
- Temperature dependence of radiation damage annealing of Silicon Photomultipliers
- Response of the first POLAR-2 Prototype to Polarized Beams
- POLAR-2, the next generation of GRB polarization detector
- First Demonstration of the Use of LG-SiPMs for Optical Readout of a TPC
- Measuring the Cosmic X-ray Background accurately
- GRBAlpha and VZLUSAT-2: GRB observations with CubeSats after 3 years of operations
- Optimizing the light output of a plastic scintillator and SiPM based detector through optical characterization and simulation: A case study for POLAR-2