Response of the first POLAR-2 Prototype to Polarized Beams
arXiv:2406.05783 · doi:10.1088/1748-0221/19/08/P08002
Abstract
POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016. POLAR-2 aims to measure the polarization of the Gamma-ray Burst prompt emission within the 30-800 keV energy range. Thanks to its high sensitivity to gamma-ray polarization, as well as its large effective area, POLAR-2 will provide the most precise measurements of this type to date. Such measurements are key to improve our understanding of the astrophysical processes responsible for Gamma-Ray Bursts. The detector consists of a segmented array of plastic scintillator bars, each one of which is read out by a Silicon PhotoMultiplier channel. The flight model of POLAR-2 will contain a total of 6400 scintillators. These are divided into 100 groups of 64 bars each, in so-called polarimeter modules. In recent years, the collaboration has designed and produced the first prototypes of these polarimeter modules and subjected these to space qualification tests. In addition, in April 2023, the first of these modules were calibrated using fully polarized gamma-ray beams at the European Synchrotron Radiation Facility (ESRF) in France. In this work, we will present the results of this calibration campaign and compare these to the simulated performance of the POLAR-2 modules. Potential improvements to the design are also discussed. Finally, the measurements are used, in combination with the verified simulation framework, to estimate the scientific performance of the full POLAR-2 detector and compare it to its predecessor.
Accepted for publication in JINST
References in corpus (18)
- GW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral
- Multi-messenger Observations of a Binary Neutron Star Merger
- Discovery of the peculiar supernova 1998bw in the error box of GRB980425
- Discovery of the X-Ray Afterglow of the Gamma-Ray Burst of February 28 1997
- The metamorphosis of SN1998bw
- On understanding the figures of merit for detection and measurement of x-ray polarization
- Detailed polarization measurements of the prompt emission of five Gamma-Ray Bursts
- The POLAR Gamma-Ray Burst Polarization Catalog
- Time-Resolved GRB Polarization with POLAR and GBM
- Design and construction of the POLAR detector
- Instrument Performance and Simulation Verification of the POLAR Detector
- In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements
- Temperature dependence of radiation damage annealing of Silicon Photomultipliers
- A crosstalk and non-uniformity correction method for the Compact Space-borne Compton Polarimeter POLAR
- Gamma-Ray Polarimetry of the Crab Pulsar Observed by POLAR
- Proton Irradiation of SiPM arrays for POLAR-2
- Gamma-ray Polarimetry of Transient Sources with POLAR
- Energy-dependent polarization of Gamma-Ray Bursts' prompt emission with the POLAR and POLAR-2 instruments
Cited by in corpus (3)
- Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions
- Optimizing the light output of a plastic scintillator and SiPM based detector through optical characterization and simulation: A case study for POLAR-2
- Design and preliminary performance study of the broad-band spectrometer detector for POLAR-2