Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
arXiv:2211.09582 · doi:10.1088/1748-0221/18/06/P06010
Abstract
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
arXiv comment19 pages, 10 figures
References in corpus (23)
- Direct Evidence for Neutrino Flavor Transformation from Neutral-Current Interactions in the Sudbury Neutrino Observatory
- Evidence for Neutrino Oscillations from the Observation of Electron Anti-neutrinos in a Muon Anti-Neutrino Beam
- The Reactor Antineutrino Anomaly
- Improved Predictions of Reactor Antineutrino Spectra
- Measurement of the solar neutrino capture rate with gallium metal. III: Results for the 2002--2007 data-taking period
- Measurement of the flux and zenith-angle distribution of upward through-going muons by Super-Kamiokande
- Improved Search for Oscillations in the MiniBooNE Experiment
- Reanalysis of the GALLEX solar neutrino flux and source experiments
- Observation of Energy and Baseline Dependent Reactor Antineutrino Disappearance in the RENO Experiment
- Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay
- Results from the Baksan Experiment on Sterile Transitions (BEST)
- First search for short-baseline neutrino oscillations at HFIR with PROSPECT
- Improved Short-Baseline Neutrino Oscillation Search and Energy Spectrum Measurement with the PROSPECT Experiment at HFIR
- Neutrino Detectors as Tools for Nuclear Security
- The PROSPECT Reactor Antineutrino Experiment
- Measurement of the Antineutrino Spectrum from U Fission at HFIR with PROSPECT
- Performance of a segmented Li-loaded liquid scintillator detector for the PROSPECT experiment
- Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment
- Joint Measurement of the U Antineutrino Spectrum by Prospect and Stereo
- PROSPECT-II Physics Opportunities
- A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector
- Comparison of weighted and unweighted histograms
- The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector