A numerical study of 21-cm signal suppression and noise increase in direction-dependent calibration of LOFAR data
arXiv:2111.02537 · doi:10.1093/mnras/stab3233
Abstract
We investigate systematic effects in direction dependent gain calibration in the context of the Low-Frequency Array (LOFAR) 21-cm Epoch of Reionization (EoR) experiment. The LOFAR EoR Key Science Project aims to detect the 21-cm signal of neutral hydrogen on interferometric baselines of . We show that suppression of faint signals can effectively be avoided by calibrating these short baselines using only the longer baselines. However, this approach causes an excess variance on the short baselines due to small gain errors induced by overfitting during calibration. We apply a regularised expectation-maximisation algorithm with consensus optimisation (sagecal-co) to real data with simulated signals to show that overfitting can be largely mitigated by penalising spectrally non-smooth gain solutions during calibration. This reduces the excess power with about a factor 4 in the simulations. Our results agree with earlier theoretical analysis of this bias-variance trade off and support the gain-calibration approach to the LOFAR 21-cm signal data.
arXiv commentThis is a pre-copyedited, author-produced PDF of an article accepted for publication in MNRAS following peer review
References in corpus (21)
- LOFAR: The LOw-Frequency ARray
- WSClean: an implementation of a fast, generic wide-field imager for radio astronomy
- 21cmFAST: A Fast, Semi-Numerical Simulation of the High-Redshift 21-cm Signal
- Hydrogen Epoch of Reionization Array (HERA)
- Reionization and Cosmology with 21 cm Fluctuations
- A morphological algorithm for improving radio-frequency interference detection
- A simulation calibrated limit on the HI power spectrum from the GMRT Epoch of Reionization experiment
- Improved upper limits on the 21-cm signal power spectrum of neutral hydrogen at from LOFAR
- Post-correlation radio frequency interference classification methods
- Upper limits on the 21-cm Epoch of Reionization power spectrum from one night with LOFAR
- Foreground simulations for the LOFAR - Epoch of Reionization Experiment
- Revisiting the radio interferometer measurement equation. I. A full-sky Jones formalism
- Toward Epoch of Reionization Measurements with Wide-Field Radio Observations
- Calibration Requirements for Detecting the 21 cm Epoch of Reionization Power Spectrum and Implications for the SKA
- Initial deep LOFAR observations of Epoch of Reionization windows: I. The North Celestial Pole
- The Impact of Modeling Errors on Interferometer Calibration for 21 cm Power Spectra
- Systematic biases in low frequency radio interferometric data due to calibration: the LOFAR EoR case
- Distributed Radio Interferometric Calibration
- Quantifying Suppression of the Cosmological 21-cm Signal due to Direction Dependent Gain Calibration in Radio Interferometers
- Precision requirements for interferometric gridding in 21-cm power spectrum analysis
- Statistical Performance of Radio Interferometric Calibration
Cited by in corpus (6)
- Validation of the HERA Phase I Epoch of Reionization 21 cm Power Spectrum Software Pipeline
- Assessing the impact of two independent direction-dependent calibration algorithms on the LOFAR 21-cm signal power spectrum
- Statistical analysis of the causes of excess variance in the 21 cm signal power spectra obtained with the Low-Frequency Array
- Probing early universe through redshifted 21-cm signal: Modelling and observational challenges
- Astrophysical information from the Rayleigh-Jeans Tail of the CMB
- Probing the Epoch of Reionization using synergies of line intensity mapping