Performance of the MICE diagnostic system
arXiv:2106.05813 · doi:10.1088/1748-0221/16/08/P08046
Abstract
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.
arXiv comment27 pages, 18 figures
References in corpus (18)
- The Upgraded D0 Detector
- Neutrino Beams from Muon Storage Rings: Characteristics and Physics Potential
- Physics at a future Neutrino Factory and super-beam facility
- The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment
- The design, construction and performance of the MICE scintillating fibre trackers
- The design and commissioning of the MICE upstream time-of-flight system
- Stochastic Cooling Overview
- A Cherenkov Radiation Detector with High Density Aerogels
- Demonstration of Muon-Beam Transverse Phase-Space Compression
- Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
- Behaviour in Magnetic Fields of Fast Conventional and Fine-Mesh Photomultipliers
- Electron-Muon Ranger: performance in the MICE Muon Beam
- The reconstruction software for the MICE scintillating fibre trackers
- Pion contamination in the MICE muon beam
- First particle-by-particle measurement of emittance in the Muon Ionization Cooling Experiment
- The design and construction of the MICE Electron-Muon Ranger
- MAUS: The MICE Analysis User Software
- The liquid-hydrogen absorber for MICE