The design, construction and performance of the MICE scintillating fibre trackers
arXiv:1005.3491 · doi:10.1016/j.nima.2011.04.041
Abstract
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.
arXiv comment43 pages, 38 figures
References in corpus (2)
Cited by in corpus (18)
- The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment
- Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
- The reconstruction software for the MICE scintillating fibre trackers
- Pion contamination in the MICE muon beam
- First particle-by-particle measurement of emittance in the Muon Ionization Cooling Experiment
- MAUS: The MICE Analysis User Software
- First demonstration of ionization cooling by the Muon Ionization Cooling Experiment
- Design and expected performance of the MICE demonstration of ionization cooling
- The liquid-hydrogen absorber for MICE
- Progress of the MICE experiment at RAL
- MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
- Novel Application of Density Estimation Techniques in Muon Ionization Cooling Experiment
- Performance of the MICE diagnostic system
- A Non-Parametric Density Estimation Approach to Measuring Beam Cooling in MICE
- Multiple Coulomb Scattering of muons in Lithium Hydride
- Prospects for Antiproton Experiments at Fermilab
- Progress of the MICE experiment
- A Wedge Test in MICE