Behaviour in Magnetic Fields of Fast Conventional and Fine-Mesh Photomultipliers
arXiv:1207.4909 · doi:10.1016/j.nima.2012.07.039
Abstract
The performance of both conventional and fine-mesh Hamamatsu photomultipliers has been measured inside moderate magnetic fields. This has allowed the test of effective shielding solutions for photomultipliers, to be used in time-of-flight detectors based on scintillation counters. Both signal amplitude reduction or deterioration of the timing properties inside magnetic fields have been investigated.
References in corpus (3)
Cited by in corpus (7)
- The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment
- Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
- Pion contamination in the MICE muon beam
- Secondary Emission Calorimetry: Fast and Radiation-Hard
- Progress of the MICE experiment at RAL
- Performance of the MICE diagnostic system
- Studies of relative gain and timing response of fine-mesh photomultiplier tubes in high magnetic fields