The polarization-encoded self-coherent camera
arXiv:2101.02954 · doi:10.1051/0004-6361/202039569
Abstract
The exploration of circumstellar environments by means of direct imaging to search for Earth-like exoplanets is one of the challenges of modern astronomy. One of the current limitations are evolving non-common path aberrations (NCPA) that originate from optics downstream of the main wavefront sensor. The self-coherent camera (SCC) is an integrated coronagraph and focal-plane wavefront sensor that generates wavefront information-encoding Fizeau fringes in the focal plane by adding a reference hole (RH) in the Lyot stop. Here, we aim to show that by featuring a polarizer in the RH and adding a polarizing beamsplitter downstream of the Lyot stop, the RH can be placed right next to the pupil. We refer to this new variant of the SCC as the polarization-encoded self-coherent camera (PESCC). We study the performance of the PESCC analytically and numerically, and compare it, where relevant, to the SCC. We show analytically that the PESCC relaxes the requirements on the focal-plane sampling and spectral resolution with respect to the SCC by a factor of 2 and 3.5, respectively. Furthermore, we find via our numerical simulations that the PESCC has effectively access to 16 times more photons, which improves the sensitivity of the wavefront sensing by a factor of . We also show that without additional measurements, the RH point-spread function (PSF) can be calibrated using PESCC images, enabling coherent differential imaging (CDI) as a contrast-enhancing post-processing technique for every observation. In idealized simulations (clear aperture, charge two vortex coronagraph, perfect DM, no noise sources other than phase and amplitude aberrations) and in circumstances similar to those of space-based systems, we show that WFSC combined with CDI can achieve a raw contrast of between 1 and 18 .
Accepted for publication in A&A. Shortened abstract. 17 pages, 21 figures
References in corpus (15)
- The Gemini Planet Imager: First Light
- Performance of the VLT Planet Finder SPHERE II. Data analysis and Results for IFS in laboratory
- The polarimetric imaging mode of VLT/SPHERE/IRDIS II: Characterization and correction of instrumental polarization effects
- The polarimetric imaging mode of VLT/SPHERE/IRDIS I: Description, data reduction and observing strategy
- Reference star differential imaging of close-in companions and circumstellar disks with the NIRC2 vortex coronagraph at W.M. Keck Observatory
- The coronagraphic Modal Wavefront Sensor: a hybrid focal-plane sensor for the high-contrast imaging of circumstellar environments
- On-sky performance of the QACITS pointing control technique with the Keck/NIRC2 vortex coronagraph
- Speckle suppression and companion detection using coherent differential imaging
- Wavefront sensing and control in space-based coronagraph instruments using Zernike's phase-contrast method
- Expected Performance of a Self-Coherent Camera
- Active minimization of non-common path aberrations in long-exposure imaging of exoplanetary systems
- High-contrast imaging at small separation: impact of the optical configuration of two deformable mirrors on dark holes
- High-Resolution Altitude Profiles of the Atmospheric Turbulence with PML at the Sutherland Observatory
- Spectral Linear Dark Field Control: Stabilizing Deep Contrast for Exoplanet Imaging Using out-of-band Speckle Field
- The Fast Atmospheric Self-Coherent Camera Technique: Laboratory Results and Future Directions