Newtonian calibrator tests during the Virgo O3 data taking
arXiv:2011.03728 · doi:10.1088/1361-6382/abe2da
Abstract
The gravitational-wave detectors outputs from the LIGO and Virgo collaborations have been a source of scientific results of prime importance in various domains such as astrophysics, cosmology or fundamental physics. With the upgrades of the detectors and their improved sensitivities, new challenges are set for these instruments calibration. A calibration method based on the local variations of the Newtonian gravitational field could be the next absolute reference of calibration for the interferometers network. We report new tests of Newtonian calibrators (NCal) on the Advanced Virgo detector performed during the LIGO-Virgo observing run O3. The NCal-induced strain on a mirror of the interferometer has been computed both using analytical calculations and numerical simulations with results in very good agreement. The strains given by the numerical model have been used to analyse the data of the NCals and have been compared to the reference method of calibration using photon radiation pressure. New methods to measure the NCal to mirror distance and the NCal offset with respect to the plane of the interferometer using two NCals are also presented and used to correct the NCal data which improves the agreement with the current Advanced Virgo reference of calibration.
References in corpus (9)
- GWTC-1: A Gravitational-Wave Transient Catalog of Compact Binary Mergers Observed by LIGO and Virgo during the First and Second Observing Runs
- A gravitational-wave standard siren measurement of the Hubble constant
- Tests of General Relativity with the Binary Black Hole Signals from the LIGO-Virgo Catalog GWTC-1
- Characterization of systematic error in Advanced LIGO calibration
- Calibration of Advanced Virgo and Reconstruction of the Gravitational Wave Signal h(t) during the Observing Run O2
- The Advanced Virgo Photon Calibrators
- First Tests of a Newtonian Calibrator on an Interferometric Gravitational Wave Detector
- Improving the absolute accuracy of the gravitational wave detectors by combining the photon pressure and gravity field calibrators
- Benefits of Artificially Generated Gravity Gradients for Interferometric Gravitational-Wave Detectors
Cited by in corpus (9)
- Parameter estimation with gravitational waves
- Review of the Advanced LIGO gravitational wave observatories leading to observing run four
- Virgo Detector Characterization and Data Quality: results from the O3 run
- Calibration Uncertainty's Impact on Gravitational-Wave Observations
- Calibration of Advanced Virgo and reconstruction of detector strain h(t) during the Observing Run O3
- Development of advanced photon calibrator for Kamioka gravitational wave detector (KAGRA)
- A Pseudo Plane-wave Gravitational Calibrator for Gravitational Wave Observatories
- Relative calibration of the LIGO and Virgo detectors using astrophysical events from their third observing run
- The Virgo Newtonian calibration system for the O4 observing run