End benches scattered light modeling and subtraction in Advanced Virgo
arXiv:2011.03539 · doi:10.1088/1361-6382/abe759
Abstract
Advanced Virgo end benches were a significant source of scattered light noise during the third observing run that lasted from April 1 2019 until March 27 2020. We describe how that noise could be subtracted using auxiliary channels during the online strain data reconstruction. We model in detail the scattered light noise coupling and demonstrate that further noise subtraction can be achieved. We also show that the fitted model parameters can be used to optically characterized the interferometer and in particular provide a novel way of establishing an absolute calibration of the detector strain data.
arXiv comment12 pages, 5 figures, Accepted in Class. Quantum Grav
References in corpus (10)
- Effects of Data Quality Vetoes on a Search for Compact Binary Coalescences in Advanced LIGO's First Observing Run
- GEO 600 and the GEO-HF upgrade program: successes and challenges
- DC readout experiment in Enhanced LIGO
- Improving the Sensitivity of Advanced LIGO Using Noise Subtraction
- Reducing Scattered Light in LIGO's Third Observing Run
- DC-readout of a signal-recycled gravitational wave detector
- The characterization of Virgo data and its impact on gravitational-wave searches
- The Advanced LIGO Photon Calibrators
- Calibration of Advanced Virgo and Reconstruction of the Gravitational Wave Signal h(t) during the Observing Run O2
- First Tests of a Newtonian Calibrator on an Interferometric Gravitational Wave Detector
Cited by in corpus (11)
- Subtracting glitches from gravitational-wave detector data during the third observing run
- Virgo Detector Characterization and Data Quality: results from the O3 run
- The Virgo O3 run and the impact of the environment
- Daily monitoring of scattered light noise due to microseismic variability at the Virgo interferometer
- ArchEnemy: Removing scattered-light glitches from gravitational wave data
- Dual balanced readout for scattered light noise mitigation in Michelson interferometers
- Calibration of Advanced Virgo and reconstruction of detector strain h(t) during the Observing Run O3
- Tunable coherence laser interferometry: demonstrating 40dB of straylight suppression and compatibility with resonant optical cavities
- A high angular resolution interferometric backscatter meter
- Low-coherence interferometric measurement of the spectral dependence of the light field backscattered by optical interfaces
- Using tunable coherence for reaching micrometer coherence lengths and suppressing stray light in a power-recycled Michelson interferometer