Tunable coherence laser interferometry: demonstrating 40dB of straylight suppression and compatibility with resonant optical cavities
arXiv:2501.11528 · doi:10.1103/PhysRevLett.134.213802
Abstract
A major limitation of laser interferometers using continuous wave lasers are parasitic light fields, such as ghost beams, scattered or stray light, which can cause non-linear noise. This is especially relevant for laser interferometric ground-based gravitational wave detectors. Increasing their sensitivity, particularly at frequencies below 10 Hz, is threatened by the influence of parasitic photons. These can up-convert low-frequency disturbances into phase and amplitude noise inside the relevant measurement band. By artificially tuning the coherence of the lasers, using pseudo-random-noise (PRN) phase modulations, this influence of parasitic fields can be suppressed. As it relies on these fields traveling different paths, it does not sacrifice the coherence for the intentional interference. We demonstrate the feasibility of this technique experimentally, achieving noise suppression levels of 40 dB in a Michelson interferometer with an artificial coherence length below 30 cm. We probe how the suppression depends on the delay mismatch and length of the PRN sequence. We also prove that optical resonators can be operated in the presence of PRN modulation by measuring the behavior of a linear cavity with and without such a modulation. By matching the resonators round-trip length and the PRN sequence repetition length, the classic response is recovered.
References in corpus (11)
- Advanced Virgo: a 2nd generation interferometric gravitational wave detector
- The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
- Reducing Scattered Light in LIGO's Third Observing Run
- The upgrade of GEO600
- Gravitational-wave physics with Cosmic Explorer: limits to low-frequency sensitivity
- Environmental Noise in Advanced LIGO Detectors
- Passive, free-space laser gyroscope
- Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector
- Reduction of Classical Measurement Noise via Quantum-Dense Metrology
- End benches scattered light modeling and subtraction in Advanced Virgo
- Dual balanced readout for scattered light noise mitigation in Michelson interferometers