High-precision -value measurement confirms the potential of Cs for antineutrino-mass detection
arXiv:2002.08282 · doi:10.1103/PhysRevLett.124.222503
Abstract
The ground-state-to-ground-state -decay -value of was directly measured for the first time utilizing the Phase-Imaging Ion-Cyclotron Resonance (PI-ICR) technique at the JYFLTRAP Penning-trap setup. It is the first direct determination of this -value and its value of 268.66(30)\,keV is a factor of three more precise than the currently adopted -value in the Atomic Mass Evaluation 2016. Moreover, the -value deduced from the -decay endpoint energy has been found to deviate from our result by approximately 6 standard deviations. The measurement confirms that the first-forbidden unique -decay transition is a candidate for antineutrino-mass measurements with an ultra-low -value of keV. This -value is almost an order of magnitude smaller than in any presently running or planned direct (anti)neutrino-mass experiment.
arXiv comment5 pages, 6 figures, 2 tables Submitted for publication to Physical Review Letters (PRL)
References in corpus (8)
- An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
- Neutrino mass limit from tritium beta decay
- Magnetic moments of the 2 states around Sn
- Value of the axial-vector coupling strength in and decays: A review
- Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry
- Preparing isomerically pure beams of short-lived nuclei at JYFLTRAP
- Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology
- A new off-line ion source facility at IGISOL
Cited by in corpus (15)
- Direct Measurements of Neutrino Mass
- Dy electron-capture: a strong new candidate for neutrino mass determination
- Direct measurement of the mass difference of As-Ge rules out As as a promising -decay candidate to determine the neutrino mass
- Updated evaluation of potential ultra-low Q value -decay candidates
- Observation of an ultra-low -value electron-capture channel decaying to As via high-precision mass measurement
- High-precision electron-capture value measurement of In for electron-neutrino mass determination
- Precise Q value measurements of Ag and Cd with the Canadian Penning trap for evaluation of potential ultra-low Q value -decays
- Direct determination of the atomic mass difference of the pairs As-Se and Tb-Gd rules out As and Tb as possible candidates for electron (anti)neutrino mass measurements
- High-precision mass measurement of Yb for verification of nonlinear isotope shift
- decay -value measurement of Cs and its implications to neutrino studies
- Identification of a potential ultra-low Q value electron capture decay branch in Se via a precise Penning trap measurement of the mass of As
- Neutrino mass measurements using cryogenic detectors
- High-precision measurements of the atomic mass and electron-capture decay value of Tc
- Ultra-low value for the allowed decay of Ag confirmed via mass measurements
- High-precision direct decay energy measurements of the electron-capture decay of Tc