90 citations · 455 across the 22 of their papers we have counts for
22 papers
Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements
M. Flayol, P. Ascher, D. D. Dao +19
Mass measurements of the ground and isomeric states of Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were me…
Binding energies, charge radii, spins and moments: odd-odd Ag isotopes and discovery of a new isomer
B. van den Borne, M. Stryjczyk, R. P. de Groote +33
We report on the masses and hyperfine structure of ground and isomeric states in Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique…
High-precision mass measurements of the ground and isomeric states in Ag
J. Ruotsalainen, D. A. Nesterenko, M. Stryjczyk +26
The masses of the ground and isomeric states in Ag have been measured using the phase-imaging ion-cyclotron-resonance technique at the JYFLTRAP double Penning trap mass…
Isomeric states of fission fragments explored via Penning trap mass spectrometry at IGISOL
A. Jaries, M. Stryjczyk, A. Kankainen +36
The masses of Br, Mo, Pd, Ag, In, Sb and their respective isomeric states have been measured with the JYFLTRAP Penning tr…
Long-sought isomer turns out to be the ground state of Cu
L. Canete, S. Giraud, A. Kankainen +17
Isomers close to the doubly magic nucleus Ni (, ) provide essential information on the shell evolution and shape coexistence far from stability. The existence of…
First investigation on the isomeric ratio in multinucleon transfer reactions: Entrance channel effects on the spin distribution
D. Kumar, T. Dickel, A. Zadvornaya +39
The multinucleon transfer (MNT) reaction approach was successfully employed for the first time to measure the isomeric ratios (IRs) of Po (25/2) isomer and its (9/2…
Mass measurements in the Sn region with the JYFLTRAP double Penning trap mass spectrometer
O. Beliuskina, D. A. Nesterenko, A. Jaries +24
We report on new precision mass measurements of neutron-rich Sb and I isotopes from the JYFLTRAP double Penning trap mass spectrometer. We confirm the value fro…
High-precision mass measurements of neutron deficient silver isotopes probe the robustness of the = 50 shell closure
Zhuang Ge, Mikael Reponen, Tommi Eronen +36
High-precision mass measurements of exotic Ag isotopes close to the line have been conducted with the JYFLTRAP double Penning trap mass spectrometer, with the sil…
Further evidence for shape coexistence in Zn near doubly-magic Ni
L. Nies, L. Canete, D. D. Dao +31
Isomers close to doubly-magic Ni provide essential information on the shell evolution and shape coexistence near the and double shell closure.…
High-precision electron-capture value measurement of In for electron-neutrino mass determination
Z. Ge, T. Eronen, A. deRoubin +12
A precise determination of the ground state In () electron capture to ground state of Cd () value has been performed utilizing the double Penning…
Novel Penning-trap techniques reveal isomeric states in In and In for the first time
D. A. Nesterenko, A. Kankainen, J. Kostensalo +21
Isomeric states in In and In have been studied with the JYFLTRAP Penning trap at the IGISOL facility. By employing novel ion manipulation techniques, different stat…
High-precision -value measurement confirms the potential of Cs for antineutrino-mass detection
A. de Roubin, J. Kostensalo, T. Eronen +9
The ground-state-to-ground-state -decay -value of was directly measured for the first time utilizing the Phase-Imaging…
Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP
M. Vilen, J. M. Kelly, A. Kankainen +16
The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eig…
A new off-line ion source facility at IGISOL
M. Vilén, L. Canete, B. Cheal +13
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams f…
The MORA project
P. Delahaye, E. Liénard, I. Moore +25
The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of…
Isomeric fission yield ratios for odd-mass Cd and In isotopes using the Phase-Imaging Ion-Cyclotron-Resonance technique
V. Rakopoulos, M. Lantz, S. Pomp +15
Isomeric yield ratios for the odd- isotopes of Cd and In from 25-MeV proton-induced fission on natural uranium have been measured at the JYFLTRAP double…
Measurement of the ground-state transition in the decay of F
O. S. Kirsebom, M. Hukkanen, A. Kankainen +36
We report the first detection of the second-forbidden, non-unique, , ground-state transition in the decay of F. A low-energy, mass-separated $^{20}\r…
First determination of -delayed multiple neutron emission beyond A = 100 through direct neutron measurement: The P value of Sb
R. Caballero-Folch, I. Dillmann, J. Agramunt +34
Background: -delayed multiple neutron emission has been observed for some nuclei with A100, with Rb being the heaviest 2n emitter measured to date. So far, only…
Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the -process calculations
M. Vilen, J. M. Kelly, A. Kankainen +16
The rare-earth peak in the -process abundance pattern depends sensitively on both the astrophysical conditions and subtle changes in nuclear structure in the region. This work t…
High-precision mass measurements for the isobaric multiplet mass equation at A = 52
D. A. Nesterenko, A. Kankainen, L. Canete +21
Masses of Co, Co, Fe, Fe, and Mn have been measured with the JYFLTRAP double Penning trap mass spectrometer. Of these, Co and $^{5…
The Advanced LIGO Photon Calibrators
S. Karki, D. Tuyenbayev, S. Kandhasamy +24
The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accura…
Mass of astrophysically relevant Cl and the breakdown of the isobaric multiplet mass equation
A. Kankainen, L. Canete, T. Eronen +9
The mass of Cl has been measured with the JYFLTRAP double Penning trap mass spectrometer at the Ion-Guide Isotope Separator On-Line (IGISOL) facility. The determined mass-ex…