Tight bound on finite-resolution quantum thermometry at low temperatures
arXiv:2001.04096 · doi:10.1103/PhysRevResearch.2.033394
Abstract
Precise thermometry is of wide importance in science and technology in general and in quantum systems in particular. Here, we investigate fundamental precision limits for thermometry on cold quantum systems, taking into account constraints due to finite measurement resolution. We derive a tight bound on the optimal precision scaling with temperature, as the temperature approaches zero. The bound can be saturated by monitoring the non-equilibrium dynamics of a single-qubit probe. We support this finding by accurate numerical simulations of a spin-boson model. Our results are relevant both fundamentally, as they illuminate the ultimate limits to quantum thermometry, and practically, in guiding the development of sensitive thermometric techniques applicable at ultracold temperatures.
arXiv comment10+3 pages, 3 figures
References in corpus (39)
- Nanometer scale quantum thermometry in a living cell
- High precision nano scale temperature sensing using single defects in diamond
- From Classical to Quantum Shannon Theory
- Efficient non-Markovian quantum dynamics using time-evolving matrix product operators
- Individual quantum probes for optimal thermometry
- Thermometry in the quantum regime: Recent theoretical progress
- Thermodynamics of precision in quantum non equilibrium steady states
- Exploiting the causal tensor network structure of quantum processes to efficiently simulate non-Markovian path integrals
- Detecting large quantum Fisher information with finite measurement precision
- Fast electron thermometry towards ultra-sensitive calorimetric detection
- Spin gradient thermometry for ultracold atoms in optical lattices
- Ideal Projective Measurements Have Infinite Resource Costs
- Quantum Limits of Thermometry
- Single-qubit thermometry
- Quantum Thermal Machine as a Thermometer
- Using polarons for sub-nK quantum non-demolition thermometry in a Bose-Einstein condensate
- Local quantum thermal susceptibility
- Collisional quantum thermometry
- Low-temperature thermometry can be enhanced by strong coupling
- Impurities as a quantum thermometer for a Bose-Einstein condensate
- Quantum thermometry by single-qubit dephasing
- Probing the temperature of cold many-body quantum systems
- Fundamental limits on low-temperature quantum thermometry with finite resolution
- Achieving the Landau bound to precision of quantum thermometry in systems with vanishing gap
- Bridging thermodynamics and metrology in non-equilibrium Quantum Thermometry
- Estimating Temperature via Sequential Measurements
- Quantum Simulation of single-qubit thermometry using linear optics
- Thermometry of ultracold atoms via non-equilibrium work distributions
- Initial System-Environment Correlations via the Transfer Tensor Method
- Signatures of a Noise-Induced Quantum Phase Transition in a Mesoscopic Metal Ring
- Enhanced precision bound of low-temperature quantum thermometry via dynamical control
- Nanosecond thermometry with Josephson junction
- A dynamical approach to ancilla assisted quantum thermometry
- Collective heat capacity for quantum thermometry and quantum engine enhancements
- Speed of qubit states during thermalisation
- On-and-off chip cooling of a Coulomb blockade thermometer down to 2.8 mK
- Universal locality of quantum thermal susceptibility
- Probing the local temperature of a 2DEG microdomain with a quantum dot: measurement of electron-phonon interaction
- On quantum interferometric measurements of temperature
Cited by in corpus (39)
- Fundamental limits in Bayesian thermometry and attainability via adaptive strategies
- Optimal Quantum Thermometry with Coarse-grained Measurements
- Bath-Induced Correlations Enhance Thermometry Precision at Low Temperatures
- Non-Markovian quantum thermometry
- Thermometry of Strongly Correlated Fermionic Quantum Systems using Impurity Probes
- Low-temperature quantum thermometry boosted by coherence generation
- Multi-spin probes for thermometry in the strong-coupling regime
- Sub-nK thermometry of an interacting -dimensional homogeneous Bose gas
- Optimal nonequilibrium thermometry in Markovian environments
- Uninformed Bayesian Quantum Thermometry
- Quantum sensing of temperature close to absolute zero in a Bose-Einstein condensate
- Non-equilibrium readiness and accuracy of Gaussian Quantum Thermometers
- Thermometry of Gaussian quantum systems using Gaussian measurements
- Optimal Thermometers with Spin Networks
- Discrimination of Ohmic thermal baths by quantum dephasing probes
- Invasiveness of non-equilibrium quantum thermometry
- Strongly coupled fermionic probe for nonequilibrium thermometry
- Continuous-variable quantum sensing of a dissipative reservoir
- Thermometry by correlated dephasing of impurities in a 1D Fermi gas
- Probe thermometry with continuous measurements
- Energy measurements remain thermometrically optimal beyond weak coupling
- Thermometry Based on a Superconducting Qubit
- Restoring metrological quantum advantage of measurement precision in noisy scenario
- Role of topology in determining the precision of a finite thermometer
- Enhancing precision of atomic clocks by tuning disorder in accessories
- Temperature-heat uncertainty relation in nonequilibrium quantum thermometry
- Relativistic quantum thermometry through a moving sensor
- Coherence-enhanced single-qubit thermometry out of equilibrium
- Single-qubit probes for temperature estimation in the presence of collective baths
- Quantum metrology of a structured reservoir
- Bayesian quantum thermometry based on thermodynamic length
- Correlated decoherence and thermometry with mobile impurities in a 1D Fermi gas
- Nonequilibrium quantum thermometry with noncommutative system-bath couplings
- Low-temperature Quantum Metrology Enhanced by Strong Couplings
- Optimal limits of continuously monitored thermometers and their Hamiltonian structure
- Non-Gaussian Dissipative Quantum Thermometry Beyond Gaussian Bounds
- Direct temperature readout in nonequilibrium quantum thermometry
- Gaussian quantum metrology in a dissipative environment
- Bending the rules of low-temperature thermometry with periodic driving