Probing the temperature of cold many-body quantum systems
arXiv:1712.03088 · doi:10.1103/PhysRevB.98.045101
Abstract
It is "conventional wisdom" that the uncertainty of local temperature measurements on equilibrium systems diverges exponentially fast as their temperature drops to zero. In contrast, some exactly solvable models showcase a more benign power-law-like scaling, when only a small non-equilibrium fragment of the equilibrium system is measured. Does this mean that a part may contain more information about the global temperature than the whole? Certainly not. Here, we resolve this apparent paradox. First, we prove that local quantum thermometry at low is exponentially inefficient in non-critical, gapped, and infinite spin and harmonic lattices. In contrast, we show through an open-system analysis, that the thermal sensitivity of a harmonic thermometer (probe) jointly equilibrated with a reservoir (sample) by means of an Ohmic coupling scheme, displays a distinctive power-law-like behavior as . To reconcile these two results, we exploit the fact that local thermometry on a harmonic chain may be viewed as a temperature measurement on an oscillator in a discretized harmonic environment: A gapped translationally invariant chain (for which low-- thermometry is indeed exponentially inefficient) maps into a non-standard open-system model where the low-frequency modes of the sample decouple from the probe. On the contrary, a gapless instance of such chain gives rise to the canonical Ohmic probe-sample interaction, which does include sample modes of arbitrarily low frequency. In this way, we show that the power-law-like thermometric performance observed in typical dissipative models stems from the fact that these are gapless and, as such, not subjected to the exponential limitations of their gapped counterparts. The key feature of many-body systems, when it comes to the ultimate limitations of low-- thermometry, is thus whether or not their energy spectrum is gapped.
9+8 pages, 6 figures; v3: Accepted version; see also related work by P.P. Hofer et al. at arXiv:1711.09827
References in corpus (7)
- Thermalization and its mechanism for generic isolated quantum systems
- Observation of strong coupling between a micromechanical resonator and an optical cavity field
- Quantum criticality as a resource for quantum estimation
- Individual quantum probes for optimal thermometry
- The equilibrium states of open quantum systems in the strong coupling regime
- Bose polaron as an instance of quantum Brownian motion
- Quantum polarization spectroscopy of ultracold spinor gases
Cited by in corpus (64)
- Quantum thermal machines and batteries
- Thermometry in the quantum regime: Recent theoretical progress
- Optimal cycles for low-dissipation heat engines
- Open quantum system dynamics and the mean force Gibbs state
- In situ thermometry of a cold Fermi gas via dephasing impurities
- Using polarons for sub-nK quantum non-demolition thermometry in a Bose-Einstein condensate
- Collisional quantum thermometry
- Weak and ultrastrong coupling limits of the quantum mean force Gibbs state
- Global Quantum Thermometry
- Fundamental limits on low-temperature quantum thermometry with finite resolution
- Charging assisted by thermalization
- Two-qubit quantum probes for the temperature of an Ohmic environment
- Enhanced precision bound of low-temperature quantum thermometry via dynamical control
- Many-body quantum thermal machines
- Fundamental limits in Bayesian thermometry and attainability via adaptive strategies
- Optimal Quantum Thermometry with Coarse-grained Measurements
- Tight bound on finite-resolution quantum thermometry at low temperatures
- Bath-Induced Correlations Enhance Thermometry Precision at Low Temperatures
- Non-Markovian quantum thermometry
- Thermometry of Strongly Correlated Fermionic Quantum Systems using Impurity Probes
- Collective heat capacity for quantum thermometry and quantum engine enhancements
- Optimal cold atom thermometry using adaptive Bayesian strategies
- Low-temperature quantum thermometry boosted by coherence generation
- Quantum parameter estimation in a dissipative environment
- Roadmap on Quantum Thermodynamics
- Sub-nK thermometry of an interacting -dimensional homogeneous Bose gas
- Multi-spin probes for thermometry in the strong-coupling regime
- Optimal nonequilibrium thermometry in Markovian environments
- Uninformed Bayesian Quantum Thermometry
- Surpassing the Thermal Cramer-Rao Bound with Collisional Thermometry
- Quantum Thermometry
- Rectification of heat currents across nonlinear quantum chains: A versatile approach beyond weak thermal contact
- Quantum sensing of temperature close to absolute zero in a Bose-Einstein condensate
- Quantifying precision loss in local quantum thermometry via diagonal discord
- Thermometry of Gaussian quantum systems using Gaussian measurements
- Quantum magnetometry using two-stroke thermal machines
- Non-Markovian temperature sensing
- Optimal Thermometers with Spin Networks
- Threshold for a discrete-variable sensor of quantum reservoirs
- Stochastic collisional quantum thermometry
- Strongly coupled fermionic probe for nonequilibrium thermometry
- Estimation of Hamiltonian parameters from thermal states
- Probe thermometry with continuous measurements
- Nearly nondestructive thermometry of labeled cold atoms and application to isotropic laser cooling
- Energy measurements remain thermometrically optimal beyond weak coupling
- Fisher information rates in sequentially measured quantum systems
- Measuring energy by measuring any other observable
- Bayesian estimation for collisional thermometry
- Quantum dissipation of planar harmonic systems: Maxwell-Chern-Simons theory
- Efficiently measuring -wave pairing and beyond in quantum gas microscopes
- Topological quantum thermometry
- Temperature-heat uncertainty relation in nonequilibrium quantum thermometry
- Long-time equilibration can determine transient thermality
- Relativistic quantum thermometry through a moving sensor
- Thermometric machine for ultraprecise thermometry of low temperatures
- Transport in Conductors and Rectifiers: Mean-Field Redfield Equations and Non-Equilibrium Green's Functions
- Thermometry with a Dissipative Heavy Impurity
- Optimal limits of continuously monitored thermometers and their Hamiltonian structure
- Highly sensitive temperature sensing via quadratic optomechanical coupling
- Nonequilibrium quantum thermometry with noncommutative system-bath couplings
- Non-Gaussian Dissipative Quantum Thermometry Beyond Gaussian Bounds
- Optimal strategies for transient and equilibrium quantum thermometry using Gaussian and non-Gaussian probes
- Direct temperature readout in nonequilibrium quantum thermometry
- Bending the rules of low-temperature thermometry with periodic driving