Suppression of Penning discharges between the KATRIN spectrometers
arXiv:1911.09633 · doi:10.1140/epjc/s10052-020-8278-y
Abstract
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of (90 C.L.) by precisely measuring the endpoint region of the tritium -decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
arXiv comment- 12 pages, 14 figures, LaTeX; typos corrected, references added; precised a few arguments, added additional discussions, results unchanged
References in corpus (11)
- Final Results from phase II of the Mainz Neutrino Mass Search in Tritium Decay
- An upper limit on electron antineutrino mass from Troitsk experiment
- Current Direct Neutrino Mass Experiments
- Focal-plane detector system for the KATRIN experiment
- Kassiopeia: A Modern, Extensible C++ Particle Tracking Package
- Particle-in-cell simulations of anomalous transport in a Penning discharge
- Commissioning of the vacuum system of the KATRIN Main Spectrometer
- The KATRIN Pre-Spectrometer at reduced Filter Energy
- Effect of a sweeping conductive wire on electrons stored in the Penning trap between the KATRIN spectrometers
- Technical design and commissioning of the KATRIN large-volume air coil system
- Muon-induced background in the KATRIN main spectrometer
Cited by in corpus (5)
- Direct neutrino-mass measurement based on 259 days of KATRIN data
- The Design, Construction, and Commissioning of the KATRIN Experiment
- Analysis methods for the first KATRIN neutrino-mass measurement
- KATRIN: Status and Prospects for the Neutrino Mass and Beyond
- Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment