Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
arXiv:1907.03078 · doi:10.1063/1.5098469
Abstract
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
References in corpus (2)
Cited by in corpus (19)
- Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
- Four wave-mixing in a microstrip kinetic inductance travelling wave parametric amplifier
- Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors
- A 4-8 GHz Kinetic Inductance Travelling-Wave Parametric Amplifier Using Four-Wave Mixing with Near Quantum-Limit Noise Performance
- Intermodulation Distortion in a Josephson Traveling Wave Parametric Amplifier
- Detector Array Readout with Traveling Wave Amplifiers
- Characterization of NbTiN films with thicknesses below 20 nm for low power kinetic inductance amplifiers
- Kinetic inductance traveling wave amplifier designs for practical microwave readout applications
- Nonlinear characteristics of Ti, Nb, and NbN superconducting resonators for parametric amplifiers
- An rf-SQUID-based traveling-wave parametric amplifier with -84 dBm input saturation power across more than one octave bandwidth
- Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
- Determining Absolute Neutrino Mass using Quantum Technologies
- Superconducting resonator parametric amplifiers with intrinsic separation of pump and signal tones
- Characterizing the Dark Count Rate of a Large-Format MKID Array
- First Principle Simulator of a Stochastically Varying Image Plane for Photon-Counting High Contrast Applications
- Magnetic-Field and Temperature Limits of a Kinetic-Inductance Traveling-Wave Parametric Amplifier
- Strongly nonlinear regime of Josephson transmission lines revealed by two-tone spectroscopy
- Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors
- Superconducting NbN Resonator Parametric Amplifiers for Millimetre Wavelengths