A 4-8 GHz Kinetic Inductance Travelling-Wave Parametric Amplifier Using Four-Wave Mixing with Near Quantum-Limit Noise Performance
arXiv:2402.11751 · doi:10.1063/5.0208110
Abstract
Kinetic inductance traveling-wave parametric amplifiers (KI-TWPA) have a wide instantaneous bandwidth with near quantum-limited performance and a relatively high dynamic range. Because of this, they are suitable readout devices for cryogenic detectors and superconducting qubits and have a variety of applications in quantum sensing. This work discusses the design, fabrication, and performance of a KI-TWPA based on four-wave mixing in a NbTiN microstrip transmission line. This device amplifies a signal band from 4 to 8~GHz without contamination from image tones, which are produced in a separate higher frequency band. The 4 - 8~GHz band is commonly used to read out cryogenic detectors, such as microwave kinetic inductance detectors (MKIDs) and Josephson junction-based qubits. We report a measured maximum gain of over 20 dB using four-wave mixing with a 1-dB gain compression point of -58 dBm at 15 dB of gain over that band. The bandwidth and peak gain are tunable by adjusting the pump-tone frequency and power. Using a Y-factor method, we measure an amplifier-added noise of photons from 4.5 - 8 GHz.
References in corpus (14)
- A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance
- Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing
- A photonic crystal Josephson traveling wave parametric amplifier
- Design and characterization of a lumped element single-ended superconducting microwave parametric amplifier with on-chip flux bias line
- Perspective on traveling wave microwave parametric amplifiers
- Broadband parametric amplifiers based on nonlinear kinetic inductance artificial transmission lines
- Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
- Dispersive Qubit Measurement by Interferometry with Parametric Amplifiers
- Heisenberg-limited qubit readout with two-mode squeezed light
- Nonlinearity and wideband parametric amplification in an NbTiN microstrip transmission line
- Kinetic Inductance Traveling Wave Amplifiers For Multiplexed Qubit Readout
- Floquet-Mode Traveling-Wave Parametric Amplifiers
- Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
- Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
Cited by in corpus (9)
- Josephson traveling-wave parametric amplifier based on low-intrinsic-loss coplanar lumped-element waveguide
- Nonlinearity of transparent SNS weak links decreases sharply with length
- Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier
- SPECTER: An Instrument Concept for CMB Spectral Distortion Measurements with Enhanced Sensitivity
- Kinetic Inductance and nonlinearity of MgB2 Films at 4K
- Nonlinear Co-simulation for Designing Kinetic Inductance Parametric Amplifiers
- Stacked Josephson junctions for quantum circuit applications
- Magnetic-Field and Temperature Limits of a Kinetic-Inductance Traveling-Wave Parametric Amplifier
- Review of Superconducting Qubit Devices and Their Large-Scale Integration