The laser-based gain monitoring system of the calorimeters in the Muon experiment at Fermilab
arXiv:1906.08432 · doi:10.1088/1748-0221/14/11/P11025
Abstract
The Muon experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term (ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon laser calibration system, showing how the experimental requirements have been met.
arXiv comment33 pages,24 figures. Matches the published version
References in corpus (12)
- Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL
- Measurement of the Negative Muon Anomalous Magnetic Moment to 0.7 ppm
- Muon (g-2) Technical Design Report
- The Muon (g-2) Theory Value: Present and Future
- Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
- Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
- Next Generation Muon g-2 Experiments
- Laser Calibration System in JUNO
- Electron beam test of key elements of the laser-based calibration system for the muon experiment
- Test of candidate light distributors for the muon (g2) laser calibration system
- Performance of the Muon calorimeter and readout systems measured with test beam data
- Geant4 simulations of the lead fluoride calorimeter
Cited by in corpus (9)
- Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
- Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
- Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
- Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
- Muon : A review
- The Straw Tracking Detector for the Fermilab Muon Experiment
- Higgsino Asymmetry and Direct-Detection Constraints of Light Dark Matter in the NMSSM with Non-Universal Higgs Masses
- Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment
- Status of the Fermilab Muon Experiment