1.3k citations · 1.9k across the 9 of their papers we have counts for
10 papers
An improved direct limit on the muon electric dipole moment
2 Collaboration, D. P. Aguillard, T. Albahri +192
A limit on the permanent electric dipole moment (EDM) of the positive muon is presented based on data from the Fermilab Muon g-2 Experiment taken between 2019 and 2020. The trackin…
Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb
2 Collaboration, D. P. Aguillard, T. Albahri +192
This report details the final measurement of the muon magnetic anomaly, , by the Muon experiment at Fermi National Accelerator Laboratory (FNAL), using positiv…
Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb
The Muon $g-2$ Collaboration, :, D. P. Aguillard +193
A new measurement of the magnetic anomaly of the positive muon is presented based on data taken from 2020 to 2023 by the Muon Experiment at Fermi National Accelerator L…
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
D. P. Aguillard, T. Albahri, D. Allspach +190
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 an…
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
D. P. Aguillard, T. Albahri, D. Allspach +188
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We ha…
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
T. Albahri, A. Anastasi, K. Badgley +174
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muo…
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
B. Abi, T. Albahri, S. Al-Kilani +234
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly . The anomaly is determined from the precision measurem…
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
T. Albahri, A. Anastasi, K. Badgley +170
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency of the muon to a combined precision of 0.46 parts per million with…
The laser-based gain monitoring system of the calorimeters in the Muon experiment at Fermilab
A. Anastasi, A. Basti, F. Bedeschi +41
The Muon experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifyin…
Performance of the Muon calorimeter and readout systems measured with test beam data
K. S. Khaw, M. Bartolini, H. Binney +31
A single calorimeter station for the Muon experiment at Fermilab includes the following subsystems: a 54-element array of PbF Cherenkov crystals read out by large-area…