Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment
arXiv:2003.06244 · doi:10.1088/1748-0221/15/11/P11008
Abstract
The E989 Muon experiment at Fermilab aims to measure the anomalous magnetic moment, , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, , and the average magnetic field in terms of the shielded proton Larmor frequency, . The measurement of with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration. A crucial element for the multi-step measurement of is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.
References in corpus (24)
- Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL
- The muon and : a new data-based analysis
- Complete Tenth-Order QED Contribution to the Muon g-2
- Refinements in electroweak contributions to the muon anomalous magnetic moment
- Reevaluation of the hadronic vacuum polarisation contributions to the Standard Model predictions of the muon g-2 and alpha(mZ) using newest hadronic cross-section data
- Hadronic light-by-light scattering contribution to the muon anomalous magnetic moment revisited
- The of charged leptons, and the hyperfine splitting of muonium
- Hadronic contribution to the muon anomalous magnetic moment to next-to-next-to-leading order
- Two-pion contribution to hadronic vacuum polarization
- A new evaluation of the hadronic vacuum polarisation contributions to the muon anomalous magnetic moment and to
- The electroweak contributions to (g-2)_μ after the Higgs boson mass measurement
- Remarks on higher-order hadronic corrections to the muon g-2
- Dispersion relation for hadronic light-by-light scattering: two-pion contributions
- The hadronic light-by-light scattering contribution to the muon anomalous magnetic moment from lattice QCD
- Three-pion contribution to hadronic vacuum polarization
- Dispersion relation for hadronic light-by-light scattering: pion pole
- Pseudoscalar-pole contribution to the : a rational approach
- Short-distance constraints for the HLbL contribution to the muon anomalous magnetic moment
- Lattice calculation of the pion transition form factor with Wilson quarks
- Longitudinal short-distance constraints for the hadronic light-by-light contribution to with large- Regge models
- Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
- Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
- The laser-based gain monitoring system of the calorimeters in the Muon experiment at Fermilab
- Performance of the Muon calorimeter and readout systems measured with test beam data
Cited by in corpus (6)
- Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
- Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
- Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
- Muon : A review
- Systematic and Statistical Uncertainties of the Hilbert-Transform Based High-precision FID Frequency Extraction Method
- High-Accuracy Absolute Magnetometry with Application to the Fermilab Muon Experiment