Photoluminescence response of acrylic (PMMA) and polytetrafluoroethylene (PTFE) to ultraviolet light
arXiv:1905.03044 · doi:10.1140/epjc/s10052-019-7152-2
Abstract
Some publications indicate that poly(methyl methacrylate) (PMMA) and polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence (fluorescence and/or phosphorescence) when irradiated with photons in the ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are commonly used to contain the liquid argon (LAr) or xenon (LXe) target material in rare-event search experiments. LAr and LXe scintillate in the vacuum UV region, and the PMMA and PTFE can be directly illuminated by these photons. Photoluminescence from support materials could cause unexpected signals in these detectors. We investigate photoluminesence in the 400 nm to 550 nm region in response to excitation with UV light between 130 nm and 250 nm at levels relevant to rare-event search experiments. Measurements are done at room temperature and the signal intensity is time-integrated over several minutes. We tested PMMA and PTFE samples from the batches used in the DEAP-3600 and LUX experiments and observed no photoluminescence signal. We put limits on the efficiency of the plastics to shift UV photons to a wavelengths region of 400 nm to 550 nm at 0.05% to 0.35% relative to the wavelength shifting efficiency of tetraphenyl-butadiene.
References in corpus (17)
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Physics reach of the XENON1T dark matter experiment
- Design and Construction of the MicroBooNE Detector
- Current Status and Future Prospects of the SNO+ Experiment
- DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
- Design and Construction of the DEAP-3600 Dark Matter Detector
- Measurements of the intrinsic quantum efficiency and absorption length of tetraphenyl butadiene thin films in the vacuum ultraviolet regime
- Two distinct components of the delayed single electron background signals in liquid xenon emission detectors
- The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Environmental Effects on TPB Wavelength-Shifting Coatings
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface
- Ion-beam excitation of liquid argon
- The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
- Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter
- MiniCLEAN Dark Matter Experiment
Cited by in corpus (6)
- R&D of Wavelength-Shifting Reflectors and Characterization of the Quantum Efficiency of Tetraphenyl Butadiene and Polyethylene Naphthalate in Liquid Argon
- Temperature-dependent fluorescence emission spectra of acrylic (PMMA) and tetraphenyl butadiene (TPB) excited with UV light
- Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K
- Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors
- Quartz fluorescence backgrounds in xenon particle detectors
- Operation of a dual-phase xenon detector with wavelength sensitivity from ultraviolet to infrared