Detector Technologies for CLIC
arXiv:1905.02520 · doi:10.23731/CYRM-2019-001
Abstract
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
152 pages, 116 figures; published as CERN Yellow Report Monograph Vol. 1/2019; corresponding editors: Dominik Dannheim, Katja Krüger, Aharon Levy, Andreas Nürnberg, Eva Sicking
References in corpus (13)
- Particle Flow Calorimetry and the PandoraPFA Algorithm
- Allpix: A Modular Simulation Framework for Silicon Detectors
- A review of advances in pixel detectors for experiments with high rate and radiation
- Experimental Tests of Particle Flow Calorimetry
- Performance of Particle Flow Calorimetry at CLIC
- Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques
- A highly granular SiPM-on-tile calorimeter prototype
- Fast Beam Conditions Monitor BCM1F for the CMS Experiment
- Software compensation in Particle Flow reconstruction
- Development of a modular test system for the silicon sensor R&D of the ATLAS Upgrade
- Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
- Commissioning of the highly granular SiW-ECAL technological prototype
- Tracking performance and simulation of capacitively coupled pixel detectors for the CLIC vertex detector
Cited by in corpus (14)
- Conformal Tracking for all-silicon trackers at future electron-positron colliders
- Mono-chromatic single photon events at the muon collider
- From precision physics to the energy frontier with the Compact Linear Collider
- Explicit form of the R-ratio of electron-positron annihilation into hadrons
- Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider
- Development of novel single-die hybridisation processes for small-pitch pixel detectors
- NLO QCD corrections to off-shell top-antitop production with semi-leptonic decays at lepton colliders
- Recurrent form of the renormalization group relations for the higher-order hadronic vacuum polarization function perturbative expansion coefficients
- Silicon Pixel R&D for the CLIC Tracking Detector
- Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement
- Silicon Vertex & Tracking Detectors for the Compact Linear Collider
- R&D for the CLIC Vertex and Tracking detectors
- Charge collection properties of TowerJazz 180 nm CMOS Pixel Sensors in dependence of pixel geometries and bias parameters, studied using a dedicated test-vehicle: the Investigator chip
- Laboratory and beam-test performance study of a 55m pitch iLGAD sensor bonded to a Timepix3 readout chip