Abstract
The data reduction procedure for radio interferometers can be viewed as a combined calibration and imaging problem. We present an algorithm that unifies cross-calibration, self-calibration, and imaging. Being a Bayesian method, that algorithm does not only calculate an estimate of the sky brightness distribution, but also provides an estimate of the joint uncertainty which entails both the uncertainty of the calibration and the one of the actual observation. The algorithm is formulated in the language of information field theory and uses Metric Gaussian Variational Inference (MGVI) as the underlying statistical method. So far only direction-independent antenna-based calibration is considered. This restriction may be released in future work. An implementation of the algorithm is contributed as well.
12 pages, 22 figures
References in corpus (4)
- WSClean: an implementation of a fast, generic wide-field imager for radio astronomy
- Revisiting the radio interferometer measurement equation. I. A full-sky Jones formalism
- Fast gain calibration in radio astronomy using alternating direction implicit methods: Analysis and applications
- Montblanc: GPU accelerated Radio Interferometer Measurement Equations in support of Bayesian Inference for Radio Observations
Cited by in corpus (23)
- First Sagittarius A* Event Horizon Telescope Results. III: Imaging of the Galactic Center Supermassive Black Hole
- On the Three-Dimensional Structure of Local Molecular Clouds
- Frankenstein: Protoplanetary disc brightness profile reconstruction at sub-beam resolution with a rapid Gaussian process
- The Photon Ring in M87*
- Hybrid Very Long Baseline Interferometry Imaging and Modeling with Themis
- Image reconstruction algorithms in radio interferometry: from handcrafted to learned regularization denoisers
- Geometric variational inference
- Deep Images of the Galactic Center with GRAVITY
- A D-term Modeling Code (DMC) for simultaneous calibration and full-Stokes imaging of very long baseline interferometric data
- Re-Envisioning Numerical Information Field Theory (NIFTy.re): A Library for Gaussian Processes and Variational Inference
- Bayesian radio interferometric imaging with direction-dependent calibration
- Assessing the impact of two independent direction-dependent calibration algorithms on the LOFAR 21-cm signal power spectrum
- Multi-scale and Multi-directional VLBI Imaging with CLEAN
- Bayesian inference of three-dimensional gas maps: II. Galactic HI
- Dynamic and polarimetric VLBI imaging with a multiscalar approach
- Bayesian self-calibration and imaging in Very Long Baseline Interferometry
- Information Field Theory and Artificial Intelligence
- Swarm intelligence for full Stokes dynamic imaging reconstruction of interferometric data
- fast-resolve: Fast Bayesian Radio Interferometric Imaging
- Prospects of using closure traces directly for imaging in Very Long Baseline Interferometry
- Robust direction-dependent gain-calibration of beam-modelling errors far from the target field
- Fast-Cadence High-Contrast Imaging with Information Field Theory
- Very-Long Baseline Interferometry Imaging with Closure Invariants using Conditional Image Diffusion