Calibration of high voltages at the ppm level by the difference of Kr conversion electron lines at the KATRIN experiment
arXiv:1802.05227 · doi:10.1140/epjc/s10052-018-5832-y
Abstract
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
arXiv comment7 pages, 5 figures
References in corpus (6)
- Final Results from phase II of the Mainz Neutrino Mass Search in Tritium Decay
- An upper limit on electron antineutrino mass from Troitsk experiment
- Current Direct Neutrino Mass Experiments
- Focal-plane detector system for the KATRIN experiment
- Precision high voltage divider for the KATRIN experiment
- Next generation KATRIN high precision voltage divider for voltages up to 65kV
Cited by in corpus (16)
- An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
- Sterile Neutrino Dark Matter
- The Design, Construction, and Commissioning of the KATRIN Experiment
- Analysis methods for the first KATRIN neutrino-mass measurement
- -Decay Spectrum, Response Function and Statistical Model for Neutrino Mass Measurements with the KATRIN Experiment
- Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN
- KATRIN: Status and Prospects for the Neutrino Mass and Beyond
- First operation of the KATRIN experiment with tritium
- High-resolution spectroscopy of gaseous Kr conversion electrons with the KATRIN experiment
- Search for Lorentz-Invariance Violation with the first KATRIN data
- A novel ppm-precise absolute calibration method for precision high-voltage dividers
- High Voltage Determination and Stabilization for Collinear Laser Spectroscopy Applications
- Shakeup and shakeoff satellite structure in the electron spectrum of Kr
- Wideband precision stabilization of the -18.6 kV retarding voltage for the KATRIN spectrometer
- Ultra-stable 3D-printed precision voltage divider for calibrations and experiments
- New Constraint on the Local Relic Neutrino Background Overdensity with the First KATRIN Data Runs